Cartridge Spool Type Shuttle Valves with All Ports Closed
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker's 3-position, 3-way spool type closed center shuttle valves can handle flows up to 175 lpm (46 gpm) and 350 bar (5000 psi) while providing precise flow control for sequencing or pressuring sensing applications within various mobile or industrial markets. These spring centered valves will shift when pressure at either end of the spool exceeds the spring setting, allowing flow from the higher pressure port to the lower pressure port, making them ideal for sensing or sequencing applications.
Markets:
• Aerial
• Construction Equipment
• Forestry Equipment
• Material Handling Equipment
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile
Features/Benefits:
• High flow capacity
• Compact cost effective design
• Various spring options available
• Hardened working parts for maximum durability
• All external parts zinc plated
Applications:
• Transmissions, hot oil shuttle
• Sequencing
Additional Technical Insight:
Available in two sizes, these valves are generally used in a transmission circuit where the excess charge pump flow is directed to a cooler. This valve will be selected by the drive side and direct the excess flow from the return side to tank.
Read More...Markets:
• Aerial
• Construction Equipment
• Forestry Equipment
• Material Handling Equipment
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile
Features/Benefits:
• High flow capacity
• Compact cost effective design
• Various spring options available
• Hardened working parts for maximum durability
• All external parts zinc plated
Applications:
• Transmissions, hot oil shuttle
• Sequencing
Additional Technical Insight:
Available in two sizes, these valves are generally used in a transmission circuit where the excess charge pump flow is directed to a cooler. This valve will be selected by the drive side and direct the excess flow from the return side to tank.
| Action | Part No. | Availability | Partner Available | Price | UOM | Standard Flow Rate Setting | Actuation Type | Seal Material | Minimum Operating Temperature | Maximum Kinematic Viscosity | Weight | Operating Temperature | For Fluid Type | Maximum Flow Rate | Operation Type | Switching Pressure | Cavity Size | Flow Rate | Configuration | Division | Maximum Operating Pressure | Filter Efficiency Rating | Maximum Inlet Pressure Rating | Function | Valve Material | Body Material | Maximum Operating Temperature | Leak Rate | Installation Torque | Seal Material | Flow Rate | Switching Pressure |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| K04C3-0.0N | Quote Required | TBD | 15 Gal/min | Pressure Sensing | Nitrile | -30 °F | 45-2000 SSU (6 to 420 cSt) | 0.37 lb | -30 to +250 °F | Mineral-based or synthetic hydraulic fluids | 26 Gal/min | Spring Centered, All Parts Closed | 0 psi | C10-4 | 100 L/min | 3-way Spool Type | Mobile Hydraulic Systems Division Europe | 420 bar | ISO 4406 18/16/13, SAE Class 4 | 6000 psi | Shuttle | All parts steel. All operating parts hardened steel | n/a | +121 °C | 100 @ 1450 PSI (100 BAR) cm3/min | 50 Nm | Nitrile | 26 GAL/MIN, 100 L/MIN | 0 PSI, 0 BAR | |||
| K04C3-0.0V | Quote Required | TBD | 15 | Pressure Sensing | Fluorocarbon | -15 | 45-2000 SSU (6 to 420 cSt) | 0.37 | -15 to +400 | Mineral-based or synthetic hydraulic fluids | 26 | Spring Centered, All Parts Closed | 0 | C10-4 | 26 | 3-way Spool Type | Mobile Hydraulic Systems Division Europe | 6000 | ISO 4406 18/16/13, SAE Class 4 | 6000 | Shuttle | All parts steel. All operating parts hardened steel | n/a | +400 | 100 @ 1450 PSI (100 BAR) | 37 | Fluorocarbon | 26 GAL/MIN, 100 L/MIN | 0 PSI, 0 BAR | |||
| K04C3-10.0N | Quote Required | 9 In Stock | $160.25 | EA | 55 L/min | Pressure Sensing | Nitrile | -34 °C | 45-2000 SSU (6 to 420 cSt) | 0.17 kg | -30 to +250 °F | Mineral-based or synthetic hydraulic fluids | 100 L/min | Spring Centered, All Parts Closed | 145 psi | C10-4 | 26 Gal/min | 3-way Spool Type | Mobile Hydraulic Systems Division Europe | 420 bar | ISO 4406 18/16/13, SAE Class 4 | 6000 psi | Shuttle | All parts steel. All operating parts hardened steel | n/a | +250 °F | 100 @ 1450 PSI (100 BAR) cm3/min | 37 lb-ft | Nitrile | 26 GAL/MIN, 100 L/MIN | 145 PSI, 10 BAR | |
| K04C3-10.0V | Quote Required | TBD | 15 | Pressure Sensing | Fluorocarbon | -15 | 45-2000 SSU (6 to 420 cSt) | 0.37 | -15 to +400 | Mineral-based or synthetic hydraulic fluids | 26 | Spring Centered, All Parts Closed | 145 | C10-4 | 26 | 3-way Spool Type | Mobile Hydraulic Systems Division Europe | 6000 | ISO 4406 18/16/13, SAE Class 4 | 6000 | Shuttle | All parts steel. All operating parts hardened steel | n/a | +400 | 100 @ 1450 PSI (100 BAR) | 37 | Fluorocarbon | 26 GAL/MIN, 100 L/MIN | 145 PSI, 10 BAR | |||
| K04C3-15.0N | Quote Required | TBD | 55 L/min | Pressure Sensing | Nitrile | -30 °F | 45-2000 SSU (6 to 420 cSt) | 0.17 kg | -34 to +121 °C | Mineral-based or synthetic hydraulic fluids | 100 L/min | Spring Centered, All Parts Closed | 15 bar | C10-4 | 26 Gal/min | 3-way Spool Type | Mobile Hydraulic Systems Division Europe | 6000 psi | ISO 4406 18/16/13, SAE Class 4 | 6000 psi | Shuttle | All parts steel. All operating parts hardened steel | n/a | +250 °F | 100 @ 1450 PSI (100 BAR) cm3/min | 37 lb-ft | Nitrile | 26 GAL/MIN, 100 L/MIN | 218 PSI, 15 BAR | |||
| K04C3-15.0V | Quote Required | TBD | 15 | Pressure Sensing | Fluorocarbon | -15 | 45-2000 SSU (6 to 420 cSt) | 0.37 | -15 to +400 | Mineral-based or synthetic hydraulic fluids | 26 | Spring Centered, All Parts Closed | 218 | C10-4 | 26 | 3-way Spool Type | Mobile Hydraulic Systems Division Europe | 6000 | ISO 4406 18/16/13, SAE Class 4 | 6000 | Shuttle | All parts steel. All operating parts hardened steel | n/a | +400 | 100 @ 1450 PSI (100 BAR) | 37 | Fluorocarbon | 26 GAL/MIN, 100 L/MIN | 218 PSI, 15 BAR | |||
| K04C3-2.5N | Quote Required | TBD | 15 Gal/min | Pressure Sensing | Nitrile | -30 °F | 45-2000 SSU (6 to 420 cSt) | 0.17 kg | -34 to +121 °C | Mineral-based or synthetic hydraulic fluids | 100 L/min | Spring Centered, All Parts Closed | 36 psi | C10-4 | 100 L/min | 3-way Spool Type | Mobile Hydraulic Systems Division Europe | 6000 psi | ISO 4406 18/16/13, SAE Class 4 | 6000 psi | Shuttle | All parts steel. All operating parts hardened steel | n/a | +121 °C | 100 @ 1450 PSI (100 BAR) cm3/min | 37 lb-ft | Nitrile | 26 GAL/MIN, 100 L/MIN | 36 PSI, 2.5 BAR | |||
| K04C3-2.5V | Quote Required | TBD | 55 L/min | Pressure Sensing | Fluorocarbon | -15 °F | 45-2000 SSU (6 to 420 cSt) | 0.37 lb | -15 to +400 °F | Mineral-based or synthetic hydraulic fluids | 26 Gal/min | Spring Centered, All Parts Closed | 36 psi | C10-4 | 26 Gal/min | 3-way Spool Type | Mobile Hydraulic Systems Division Europe | 420 bar | ISO 4406 18/16/13, SAE Class 4 | 6000 psi | Shuttle | All parts steel. All operating parts hardened steel | n/a | +204 °C | 100 @ 1450 PSI (100 BAR) cm3/min | 50 Nm | Fluorocarbon | 26 GAL/MIN, 100 L/MIN | 36 PSI, 2.5 BAR | |||
| K04C3-5.0N | Quote Required | $192.25 | EA | 15 Gal/min | Pressure Sensing | Nitrile | -30 °F | 45-2000 SSU (6 to 420 cSt) | 0.37 lb | -34 to +121 °C | Mineral-based or synthetic hydraulic fluids | 100 L/min | Spring Centered, All Parts Closed | 5 bar | C10-4 | 100 L/min | 3-way Spool Type | Mobile Hydraulic Systems Division Europe | 6000 psi | ISO 4406 18/16/13, SAE Class 4 | 6000 psi | Shuttle | All parts steel. All operating parts hardened steel | n/a | +121 °C | 100 @ 1450 PSI (100 BAR) cm3/min | 37 lb-ft | Nitrile | 26 GAL/MIN, 100 L/MIN | 73 PSI, 5 BAR | ||
| K04C3-5.0V | Quote Required | TBD | 15 Gal/min | Pressure Sensing | Fluorocarbon | -26 °C | 45-2000 SSU (6 to 420 cSt) | 0.17 kg | -26 to +204 °C | Mineral-based or synthetic hydraulic fluids | 100 L/min | Spring Centered, All Parts Closed | 5 bar | C10-4 | 26 Gal/min | 3-way Spool Type | Mobile Hydraulic Systems Division Europe | 6000 psi | ISO 4406 18/16/13, SAE Class 4 | 420 bar | Shuttle | All parts steel. All operating parts hardened steel | n/a | +204 °C | 100 @ 1450 PSI (100 BAR) cm3/min | 37 lb-ft | Fluorocarbon | 26 GAL/MIN, 100 L/MIN | 73 PSI, 5 BAR | |||
| K3A125-1.0N | Quote Required | TBD | 105 L/min | Pressure Sensing | Nitrile | -34 °C | 45-2000 SSU (6 to 420 cSt) | 0.7 lb | -30 to +250 °F | Mineral-based or synthetic hydraulic fluids | 46 Gal/min | Spring Centered, All Parts Closed | 15 psi | 3U | 46 Gal/min | 3-way Spool Type | Mobile Hydraulic Systems Division Europe | 5000 psi | ISO 4406 18/16/13, SAE Class 4 | 5000 psi | Shuttle | All parts steel. All operating parts hardened steel | n/a | +250 °F | 300 @ 1450 PSI (100 BAR) cm3/min | 85 Nm | Nitrile | 46 GAL/MIN, 175 L/MIN | 15 PSI, 1 BAR | |||
| K3A125-1.0V | Quote Required | TBD | 105 L/min | Pressure Sensing | Fluorocarbon | -15 °F | 45-2000 SSU (6 to 420 cSt) | 0.7 lb | -15 to +400 °F | Mineral-based or synthetic hydraulic fluids | 46 Gal/min | Spring Centered, All Parts Closed | 1 bar | 3U | 175 L/min | 3-way Spool Type | Mobile Hydraulic Systems Division Europe | 350 bar | ISO 4406 18/16/13, SAE Class 4 | 350 bar | Shuttle | All parts steel. All operating parts hardened steel | n/a | +204 °C | 300 @ 1450 PSI (100 BAR) cm3/min | 85 Nm | Fluorocarbon | 46 GAL/MIN, 175 L/MIN | 15 PSI, 1 BAR | |||
| K3A125-9.0N | Quote Required | TBD | 28 Gal/min | Pressure Sensing | Nitrile | -34 °C | 45-2000 SSU (6 to 420 cSt) | 0.32 kg | -34 to +121 °C | Mineral-based or synthetic hydraulic fluids | 175 L/min | Spring Centered, All Parts Closed | 9 bar | 3U | 175 L/min | 3-way Spool Type | Mobile Hydraulic Systems Division Europe | 5000 psi | ISO 4406 18/16/13, SAE Class 4 | 5000 psi | Shuttle | All parts steel. All operating parts hardened steel | n/a | +121 °C | 300 @ 1450 PSI (100 BAR) cm3/min | 85 Nm | Nitrile | 46 GAL/MIN, 175 L/MIN | 130 PSI, 9 BAR | |||
| K3A125-9.0V | Quote Required | TBD | 28 | Pressure Sensing | Fluorocarbon | -15 | 45-2000 SSU (6 to 420 cSt) | 0.7 | -15 to +400 | Mineral-based or synthetic hydraulic fluids | 46 | Spring Centered, All Parts Closed | 130 | 3U | 46 | 3-way Spool Type | Mobile Hydraulic Systems Division Europe | 5000 | ISO 4406 18/16/13, SAE Class 4 | 5000 | Shuttle | All parts steel. All operating parts hardened steel | n/a | +400 | 300 @ 1450 PSI (100 BAR) | 63 | Fluorocarbon | 46 GAL/MIN, 175 L/MIN | 130 PSI, 9 BAR |