BioGas AK Siloxane Removal System

Picture for category BioGas AK Siloxane Removal System

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Landfill and sewage gas used in the bioGas to energy industry is becoming increasingly contaminated with Siloxanes. The only permanent solution is to remove them before they reach the engine.

The Parker PpTek BioGas AK is an inline regenerative adsorption system that will chemically remove siloxanes from the BioGas, allowing engines to operate deposit free and helping to reduce emissions.

Fitted in the fuel supply line of a bioGas to energy plant BioGas AK decontaminates landfill and sewage gas of siloxanes and other VOC’s. Simple, compact, robust, self contained & regenerative, the system enables extended full-power operation, increased service intervals and payback within an operating period as short as 12 months. The media is hydrophobic repelling water consequently no costly chiller is required to remove moisture.

Depending on the levels of contamination, the change over and regeneration cycle will be programmed to take place every 12 - 24 hours. On a site with average levels of contamination the filter medium will last three years, requiring a minimum of servicing, significantly reducing downtime and the constant removal and disposal of contaminated filter media.

Features / Benefits:

• Low ongoing maintenance costs

• Media guaranteed for 5 years

• Small outline and footprint

• Stainless steel construction

• Environmentally safe

For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceWeightPort ConnectionMaterials of ConstructionWidthMaximum Operating TemperatureBrandDivisionElectrical RequirementsHeightMaximum Flow RatePower ConsumptionLengthMaximum Operating PressureMaximum Flow Rate (m³/h)
BGAKC 1200
Quote Required
TBD
1500 to 1700DN150 PN16 flangesStainless Steel2.540HirossGas Separation and Filtration Division EMEA3 phase 50 Amp / phase2.670620 kW for 120 mins/day3.50.41200
BGAKC 2000
Quote Required
TBD
1800 to 2000DN150 PN16 flangesStainless Steel2.540HirossGas Separation and Filtration Division EMEA3 phase 50 Amp / phase2.6117720 kW for 120 mins/day3.50.42000
BGAKC 2400
Quote Required
TBD
1800 to 2000DN150 PN16 flangesStainless Steel2.540HirossGas Separation and Filtration Division EMEA3 phase 50 Amp / phase2.6153020 kW for 120 mins/day3.50.42600
BGAKC 3000
Quote Required
TBD
2800 to 3500DN200 PN10 flangesStainless Steel2.540HirossGas Separation and Filtration Division EMEA3 phase 50 Amp / phase2.6176520 kW for 120 mins/day3.50.43000
BGAKC 4000
Quote Required
TBD
2800 to 3500DN200 PN10 flangesStainless Steel2.540HirossGas Separation and Filtration Division EMEA3 phase 50 Amp / phase2.6235420 kW for 120 mins/day3.50.44000
BGAKC 5000
Quote Required
TBD
2800 to 3500DN200 PN10 flangesStainless Steel2.540HirossGas Separation and Filtration Division EMEA3 phase 50 Amp / phase2.6294220 kW for 120 mins/day3.50.45000
BGAKC 600
Quote Required
TBD
1500 to 1700DN150 PN16 flangesStainless Steel2.540HirossGas Separation and Filtration Division EMEA3 phase 50 Amp / phase2.638220 kW for 120 mins/day3.50.4650