- Availability & Price
- Search SKU
Filter by attributes
- Maximum Flow Rate
- Maximum Operating Pressure
- Mounting Type
- Size
Filter by manufacturer
Air Operated Directional Control Valve - D81VA Series
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker’s D81VA directional control valves are available in 2 or 3-position. They are manifold or subplate mounted valves which conform to NFPA’s D08, CETOP 8 mounting patterns.
Markets:
• Entertainment Automation
• Factory Automation
• Lumber & Wood
• Machine Tools
• Marine
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Processing
• Molding
• Oil & Gas
• Other Natural Resources
• Packaging Machinery
• Plastic Packaging
• Power Generation
• Primary Metal Refining/Process
• Printing and Marking Equipment
• Rubber & Tire Processing
• Vehicle Assembly Facilities
Features/Benefits:
• Low pressure drop design
• Fast response option available
• Hardened spools provide long life
Applications:
• Suitable for general hydraulic applications
Read More...Markets:
• Entertainment Automation
• Factory Automation
• Lumber & Wood
• Machine Tools
• Marine
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Processing
• Molding
• Oil & Gas
• Other Natural Resources
• Packaging Machinery
• Plastic Packaging
• Power Generation
• Primary Metal Refining/Process
• Printing and Marking Equipment
• Rubber & Tire Processing
• Vehicle Assembly Facilities
Features/Benefits:
• Low pressure drop design
• Fast response option available
• Hardened spools provide long life
Applications:
• Suitable for general hydraulic applications
| Action | Part No. | Availability | Partner Available | Price | Seal Material | Maximum Operating Temperature | Maximum Operating Pressure | Division | Maximum Flow Rate | Minimum Operating Temperature | Actuation Type | Mounting Type | Size | Body Material | Options | Valve Type | Pilot Inlet / Drain Locations | Spool Code | Spool Position | Weight | Mounting Type | Maximum Flow Rate | Maximum Operating Pressure | Size |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| D81VA009C1N89 | Quote Required | TBD | Nitrile | 140 | 5000 | Hydraulic Valve Systems Division | 80 | -4 | Hydraulic Pressure | Subplate | NFPA D08 | Gray Iron | Stroke Adjust A and B Ends | Air Operated Directional Control Valve | Internal Pilot / External Drain | 3-Position | 3-Position | 43.9 | Subplate | 80 GPM | 5000 PSI/345 Bar | NFPA D08, CETOP 8, DIN NG425 | ||
| D81VA009C1N9 | Quote Required | TBD | Nitrile | 140 | 5000 | Hydraulic Valve Systems Division | 80 | -4 | Hydraulic Pressure | Subplate | NFPA D08 | Gray Iron | Stroke Adjust A End | Air Operated Directional Control Valve | Internal Pilot / External Drain | A & B Blocked | 3-Position | 43.9 | Subplate | 80 GPM | 5000 PSI/345 Bar | NFPA D08, CETOP 8, DIN NG426 | ||
| D81VA009C1V | Quote Required | TBD | Fluorocarbon | 140 | 5000 | Hydraulic Valve Systems Division | 80 | -4 | Hydraulic Pressure | Subplate | NFPA D08 | Gray Iron | n/a | Air Operated Directional Control Valve | Internal Pilot / External Drain | P to T | 3-Position | 43.9 | Subplate | 80 GPM | 5000 PSI/345 Bar | NFPA D08, CETOP 8, DIN NG427 | ||
| D81VA009C1V60 | Quote Required | TBD | Fluorocarbon | 140 | 5000 | Hydraulic Valve Systems Division | 80 | -4 | Hydraulic Pressure | Subplate | NFPA D08 | Gray Iron | Pilot Choke Meter-in | Air Operated Directional Control Valve | Internal Pilot / External Drain | P to T | 3-Position | 43.9 | Subplate | 80 GPM | 5000 PSI/345 Bar | NFPA D08, CETOP 8, DIN NG428 | ||
| D81VA009C1V7 | Quote Required | TBD | Fluorocarbon | 140 | 5000 | Hydraulic Valve Systems Division | 80 | -4 | Hydraulic Pressure | Subplate | NFPA D08 | Gray Iron | Pilot Choke Meter-out | Air Operated Directional Control Valve | Internal Pilot / External Drain | 3-Position | 3-Position | 43.9 | Subplate | 80 GPM | 5000 PSI/345 Bar | NFPA D08, CETOP 8, DIN NG429 | ||
| D81VA009C1V8 | Quote Required | TBD | Fluorocarbon | 140 | 5000 | Hydraulic Valve Systems Division | 80 | -4 | Hydraulic Pressure | Subplate | NFPA D08 | Gray Iron | Stroke Adjust B End | Air Operated Directional Control Valve | Internal Pilot / External Drain | P to T | 3-Position | 43.9 | Subplate | 80 GPM | 5000 PSI/345 Bar | NFPA D08, CETOP 8, DIN NG430 | ||
| D81VA009C1V89 | Quote Required | TBD | Fluorocarbon | 140 | 5000 | Hydraulic Valve Systems Division | 80 | -4 | Hydraulic Pressure | Subplate | NFPA D08 | Gray Iron | Stroke Adjust A and B Ends | Air Operated Directional Control Valve | Internal Pilot / External Drain | 3-Position | 3-Position | 43.9 | Subplate | 80 GPM | 5000 PSI/345 Bar | NFPA D08, CETOP 8, DIN NG431 | ||
| D81VA009C1V9 | Quote Required | TBD | Fluorocarbon | 140 | 5000 | Hydraulic Valve Systems Division | 80 | -4 | Hydraulic Pressure | Subplate | NFPA D08 | Gray Iron | Stroke Adjust A End | Air Operated Directional Control Valve | Internal Pilot / External Drain | 3-Position | 3-Position | 43.9 | Subplate | 80 GPM | 5000 PSI/345 Bar | NFPA D08, CETOP 8, DIN NG432 | ||
| D81VA009C2N | Quote Required | TBD | Nitrile | 140 | 5000 | Hydraulic Valve Systems Division | 80 | -4 | Hydraulic Pressure | Subplate | NFPA D08 | Gray Iron | n/a | Air Operated Directional Control Valve | External Pilot / External Drain | 3-Position | 3-Position | 43.9 | Subplate | 80 GPM | 5000 PSI/345 Bar | NFPA D08, CETOP 8, DIN NG433 | ||
| D81VA009C2N60 | Quote Required | TBD | Nitrile | 140 | 5000 | Hydraulic Valve Systems Division | 80 | -4 | Hydraulic Pressure | Subplate | NFPA D08 | Gray Iron | Pilot Choke Meter-in | Air Operated Directional Control Valve | External Pilot / External Drain | P to T | Spring Centered | 43.9 | Subplate | 80 GPM | 5000 PSI/345 Bar | NFPA D08, CETOP 8, DIN NG434 | ||
| D81VA009C2N7 | Quote Required | TBD | Nitrile | 140 | 5000 | Hydraulic Valve Systems Division | 80 | -4 | Hydraulic Pressure | Subplate | NFPA D08 | Gray Iron | Pilot Choke Meter-out | Air Operated Directional Control Valve | External Pilot / External Drain | 3-Position | 3-Position | 43.9 | Subplate | 80 GPM | 5000 PSI/345 Bar | NFPA D08, CETOP 8, DIN NG435 | ||
| D81VA009C2N8 | Quote Required | TBD | Nitrile | 140 | 5000 | Hydraulic Valve Systems Division | 80 | -4 | Hydraulic Pressure | Subplate | NFPA D08 | Gray Iron | Stroke Adjust B End | Air Operated Directional Control Valve | External Pilot / External Drain | 3-Position | 3-Position | 43.9 | Subplate | 80 GPM | 5000 PSI/345 Bar | NFPA D08, CETOP 8, DIN NG436 | ||
| D81VA009C2N89 | Quote Required | TBD | Nitrile | 140 | 5000 | Hydraulic Valve Systems Division | 80 | -4 | Hydraulic Pressure | Subplate | NFPA D08 | Gray Iron | Stroke Adjust A and B Ends | Air Operated Directional Control Valve | External Pilot / External Drain | 3-Position | 3-Position | 43.9 | Subplate | 80 GPM | 5000 PSI/345 Bar | NFPA D08, CETOP 8, DIN NG437 | ||
| D81VA009C2N9 | Quote Required | TBD | Nitrile | 140 | 5000 | Hydraulic Valve Systems Division | 80 | -4 | Hydraulic Pressure | Subplate | NFPA D08 | Gray Iron | Stroke Adjust A End | Air Operated Directional Control Valve | External Pilot / External Drain | 3-Position | 3-Position | 43.9 | Subplate | 80 GPM | 5000 PSI/345 Bar | NFPA D08, CETOP 8, DIN NG438 | ||
| D81VA009C2V | Quote Required | TBD | Fluorocarbon | 140 | 5000 | Hydraulic Valve Systems Division | 80 | -4 | Hydraulic Pressure | Subplate | NFPA D08 | Gray Iron | n/a | Air Operated Directional Control Valve | External Pilot / External Drain | A & B Blocked | 3-Position | 43.9 | Subplate | 80 GPM | 5000 PSI/345 Bar | NFPA D08, CETOP 8, DIN NG439 | ||
| D81VA009C2V60 | Quote Required | TBD | Fluorocarbon | 140 | 5000 | Hydraulic Valve Systems Division | 80 | -4 | Hydraulic Pressure | Subplate | NFPA D08 | Gray Iron | Pilot Choke Meter-in | Air Operated Directional Control Valve | External Pilot / External Drain | 3-Position | 3-Position | 43.9 | Subplate | 80 GPM | 5000 PSI/345 Bar | NFPA D08, CETOP 8, DIN NG440 | ||
| D81VA009C2V7 | Quote Required | TBD | Fluorocarbon | 140 | 5000 | Hydraulic Valve Systems Division | 80 | -4 | Hydraulic Pressure | Subplate | NFPA D08 | Gray Iron | Pilot Choke Meter-out | Air Operated Directional Control Valve | External Pilot / External Drain | 3-Position | 3-Position | 43.9 | Subplate | 80 GPM | 5000 PSI/345 Bar | NFPA D08, CETOP 8, DIN NG441 | ||
| D81VA009C2V8 | Quote Required | TBD | Fluorocarbon | 140 | 5000 | Hydraulic Valve Systems Division | 80 | -4 | Hydraulic Pressure | Subplate | NFPA D08 | Gray Iron | Stroke Adjust B End | Air Operated Directional Control Valve | External Pilot / External Drain | P to T | 3-Position | 43.9 | Subplate | 80 GPM | 5000 PSI/345 Bar | NFPA D08, CETOP 8, DIN NG442 | ||
| D81VA009C2V89 | Quote Required | TBD | Fluorocarbon | 140 | 5000 | Hydraulic Valve Systems Division | 80 | -4 | Hydraulic Pressure | Subplate | NFPA D08 | Gray Iron | Stroke Adjust A and B Ends | Air Operated Directional Control Valve | External Pilot / External Drain | 3-Position | 3-Position | 43.9 | Subplate | 80 GPM | 5000 PSI/345 Bar | NFPA D08, CETOP 8, DIN NG443 | ||
| D81VA009C2V9 | Quote Required | TBD | Fluorocarbon | 140 | 5000 | Hydraulic Valve Systems Division | 80 | -4 | Hydraulic Pressure | Subplate | NFPA D08 | Gray Iron | Stroke Adjust A End | Air Operated Directional Control Valve | External Pilot / External Drain | 3-Position | 3-Position | 43.9 | Subplate | 80 GPM | 5000 PSI/345 Bar | NFPA D08, CETOP 8, DIN NG444 |