Air-Oil Unit Model:AHU2-063 (Convertor Capacity 0.16~1.6L)

Picture for category Air-Oil Unit Model:AHU2-063 (Convertor Capacity 0.16~1.6L)

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The AHU2 series is an Air-Oil Unit that converts pneumatic pressure into hydraulic control for constant speed control and arbitrary stop. Combinations such as those with flow control valves, those with throttle valves, and converters only are possible. It exerts more power when used in combination with our low-pressure hydraulic cylinder.


Markets:

・General Industry

・Machine Tools


Applications:

・General Industry

・Factory Automation

・Machine Tools


Features/Benefits:

・Because of hydraulic control, speed control is easy.

・With flow control, throttle, skip and stop valve, etc., select according to the application.

・The converter capacity is 0.16 to 20L.

・Some types are available with a switch.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePricePilot Pressure RatioLiquid Inlet Port SizeProof PressureSupply Air Inlet Port SizeMaximum Operating PressureDivisionOperating TemperaturePilot Port SizeFor Fluid TypeProduct StyleMinimum Opening PressureCapacityAssembled Combined Valve TypeDiameterAssembled Control Valve TypeSensor typeOptional AccessoriesInput VoltageMaximum Flow Rate (lpm)Sensor Connection
H3FG00015119
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaRc1/21.5 MPaRc3/81 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc1/8Petroleum-based FluidAir-Oil converter0.2 MPa0.63 LNomal Close Skip Valve/Normal Open Stop Valve63 mmFlow control(Meter-in control)no sensorN/AAC100V 50/60Hz40no sensor
H3FG00015120
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaRc1/21.5 MPaRc3/81 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc1/8Petroleum-based FluidAir-Oil converter0.2 MPa0.63 LNomal Close Skip Valve/Normal Open Stop Valve63 mmFlow control(Meter-in control)1 sensorN/AAC100V 50/60Hz40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)
H3FG00015121
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaRc1/21.5 MPaRc3/81 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc1/8Petroleum-based FluidAir-Oil converter0.2 MPa0.63 LNomal Close Skip Valve/Normal Open Stop Valve63 mmFlow control(Meter-in control)2 sensorsN/AAC100V 50/60Hz40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)
H3FG00015122
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaRc1/21.5 MPaRc3/81 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc1/8Petroleum-based FluidAir-Oil converter0.2 MPa0.63 LNomal Close Skip Valve/Normal Open Stop Valve63 mmFlow control(Meter-in control)3 sensorsN/AAC100V 50/60Hz40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)
H3FG00015123
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaRc1/21.5 MPaRc3/81 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc1/8Petroleum-based FluidAir-Oil converter0.2 MPa0.63 LNomal Close Skip Valve/Normal Open Stop Valve63 mmFlow control(Meter-in control)4 sensorsN/AAC100V 50/60Hz40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)
H3FG00015124
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaRc1/21.5 MPaRc3/81 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc1/8Petroleum-based FluidAir-Oil converter0.2 MPa0.63 LNomal Close Skip Valve/Normal Open Stop Valve63 mmFlow control(Meter-in control)no sensorN/AAC200V 50/60Hz40no sensor
H3FG00015125
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaRc1/21.5 MPaRc3/81 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc1/8Petroleum-based FluidAir-Oil converter0.2 MPa0.63 LNomal Close Skip Valve/Normal Open Stop Valve63 mmFlow control(Meter-in control)1 sensorN/AAC200V 50/60Hz40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)
H3FG00015126
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaRc1/21.5 MPaRc3/81 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc1/8Petroleum-based FluidAir-Oil converter0.2 MPa0.63 LNomal Close Skip Valve/Normal Open Stop Valve63 mmFlow control(Meter-in control)2 sensorsN/AAC200V 50/60Hz40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)
H3FG00015127
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaRc1/21.5 MPaRc3/81 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc1/8Petroleum-based FluidAir-Oil converter0.2 MPa0.63 LNomal Close Skip Valve/Normal Open Stop Valve63 mmFlow control(Meter-in control)3 sensorsN/AAC200V 50/60Hz40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)
H3FG00015128
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaRc1/21.5 MPaRc3/81 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc1/8Petroleum-based FluidAir-Oil converter0.2 MPa0.63 LNomal Close Skip Valve/Normal Open Stop Valve63 mmFlow control(Meter-in control)4 sensorsN/AAC200V 50/60Hz40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)
H3FG00015129
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaRc1/21.5 MPaRc3/81 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc1/8Petroleum-based FluidAir-Oil converter0.2 MPa0.63 LNomal Close Skip Valve/Normal Open Stop Valve63 mmFlow control(Meter-in control)no sensorN/ADC24V40no sensor
H3FG00015130
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaRc1/21.5 MPaRc3/81 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc1/8Petroleum-based FluidAir-Oil converter0.2 MPa0.63 LNomal Close Skip Valve/Normal Open Stop Valve63 mmFlow control(Meter-in control)1 sensorN/ADC24V40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)
H3FG00015131
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaRc1/21.5 MPaRc3/81 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc1/8Petroleum-based FluidAir-Oil converter0.2 MPa0.63 LNomal Close Skip Valve/Normal Open Stop Valve63 mmFlow control(Meter-in control)2 sensorsN/ADC24V40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)
H3FG00015132
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaRc1/21.5 MPaRc3/81 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc1/8Petroleum-based FluidAir-Oil converter0.2 MPa0.63 LNomal Close Skip Valve/Normal Open Stop Valve63 mmFlow control(Meter-in control)3 sensorsN/ADC24V40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)
H3FG00015133
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaRc1/21.5 MPaRc3/81 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc1/8Petroleum-based FluidAir-Oil converter0.2 MPa0.63 LNomal Close Skip Valve/Normal Open Stop Valve63 mmFlow control(Meter-in control)4 sensorsN/ADC24V40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)
H3FG00015134
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaRc1/21.5 MPaRc3/81 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc1/8Petroleum-based FluidAir-Oil converter0.2 MPa0.63 LNomal Close Skip Valve63 mmFlow control(Meter-out control)no sensorN/AAC100V 50/60Hz40no sensor
H3FG00015135
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaRc1/21.5 MPaRc3/81 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc1/8Petroleum-based FluidAir-Oil converter0.2 MPa0.63 LNomal Close Skip Valve63 mmFlow control(Meter-out control)1 sensorN/AAC100V 50/60Hz40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)
H3FG00015136
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaRc1/21.5 MPaRc3/81 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc1/8Petroleum-based FluidAir-Oil converter0.2 MPa0.63 LNomal Close Skip Valve63 mmFlow control(Meter-out control)2 sensorsN/AAC100V 50/60Hz40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)
H3FG00015137
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaRc1/21.5 MPaRc3/81 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc1/8Petroleum-based FluidAir-Oil converter0.2 MPa0.63 LNomal Close Skip Valve63 mmFlow control(Meter-out control)3 sensorsN/AAC100V 50/60Hz40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)
H3FG00015138
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaRc1/21.5 MPaRc3/81 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc1/8Petroleum-based FluidAir-Oil converter0.2 MPa0.63 LNomal Close Skip Valve63 mmFlow control(Meter-out control)4 sensorsN/AAC100V 50/60Hz40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)