Air-Oil Unit Model:AHU2-063 (Convertor Capacity 0.16~1.6L)
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
The AHU2 series is an Air-Oil Unit that converts pneumatic pressure into hydraulic control for constant speed control and arbitrary stop. Combinations such as those with flow control valves, those with throttle valves, and converters only are possible. It exerts more power when used in combination with our low-pressure hydraulic cylinder.
Markets:
・General Industry
・Machine Tools
Applications:
・General Industry
・Factory Automation
・Machine Tools
Features/Benefits:
・Because of hydraulic control, speed control is easy.
・With flow control, throttle, skip and stop valve, etc., select according to the application.
・The converter capacity is 0.16 to 20L.
・Some types are available with a switch.
Read More...Markets:
・General Industry
・Machine Tools
Applications:
・General Industry
・Factory Automation
・Machine Tools
Features/Benefits:
・Because of hydraulic control, speed control is easy.
・With flow control, throttle, skip and stop valve, etc., select according to the application.
・The converter capacity is 0.16 to 20L.
・Some types are available with a switch.
| Action | Part No. | Availability | Partner Available | Price | For Fluid Type | Pilot Port Size | Division | Operating Temperature | Maximum Operating Pressure | Supply Air Inlet Port Size | Proof Pressure | Liquid Inlet Port Size | Pilot Pressure Ratio | Minimum Opening Pressure | Product Style | Assembled Combined Valve Type | Input Voltage | Capacity | Sensor type | Assembled Control Valve Type | Diameter | Maximum Flow Rate (lpm) | Sensor Connection | Optional Accessories |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| H3FG00013879 | Quote Required | TBD | Petroleum-based Fluid | Rc1/8 | TAIYO Division | -5 ~+50 °C (No freezing) | 1 MPa | Rc3/8 | 1.5 MPa | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 0.2 MPa | Air-Oil converter | Normal Open Stop Valve | DC24V | 0.16 L | no sensor | Flow control(Meter-in control) | 63 mm | 40 | no sensor | N/A | ||
| H3FG00013880 | Quote Required | TBD | Petroleum-based Fluid | Rc1/8 | TAIYO Division | -5 ~+50 °C (No freezing) | 1 MPa | Rc3/8 | 1.5 MPa | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 0.2 MPa | Air-Oil converter | Normal Open Stop Valve | DC24V | 0.16 L | 1 sensor | Flow control(Meter-in control) | 63 mm | 40 | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | N/A | ||
| H3FG00013881 | Quote Required | TBD | Petroleum-based Fluid | Rc1/8 | TAIYO Division | -5 ~+50 °C (No freezing) | 1 MPa | Rc3/8 | 1.5 MPa | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 0.2 MPa | Air-Oil converter | Normal Open Stop Valve | DC24V | 0.16 L | 2 sensors | Flow control(Meter-in control) | 63 mm | 40 | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | N/A | ||
| H3FG00013882 | Quote Required | TBD | Petroleum-based Fluid | Rc1/8 | TAIYO Division | -5 ~+50 °C (No freezing) | 1 MPa | Rc3/8 | 1.5 MPa | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 0.2 MPa | Air-Oil converter | Normal Open Stop Valve | DC24V | 0.16 L | 3 sensors | Flow control(Meter-in control) | 63 mm | 40 | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | N/A | ||
| H3FG00013883 | Quote Required | TBD | Petroleum-based Fluid | Rc1/8 | TAIYO Division | -5 ~+50 °C (No freezing) | 1 MPa | Rc3/8 | 1.5 MPa | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 0.2 MPa | Air-Oil converter | Normal Open Stop Valve | DC24V | 0.16 L | 4 sensors | Flow control(Meter-in control) | 63 mm | 40 | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | N/A | ||
| H3FG00013884 | Quote Required | TBD | Petroleum-based Fluid | Rc1/8 | TAIYO Division | -5 ~+50 °C (No freezing) | 1 MPa | Rc3/8 | 1.5 MPa | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 0.0 MPa | Air-Oil converter | Nomal Close Stop Valve | AC100V 50/60Hz | 0.16 L | no sensor | Without flow valve | 63 mm | 40 | no sensor | N/A | ||
| H3FG00013885 | Quote Required | TBD | Petroleum-based Fluid | Rc1/8 | TAIYO Division | -5 ~+50 °C (No freezing) | 1 MPa | Rc3/8 | 1.5 MPa | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 0.0 MPa | Air-Oil converter | Nomal Close Stop Valve | AC100V 50/60Hz | 0.16 L | 1 sensor | Without flow valve | 63 mm | 40 | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | N/A | ||
| H3FG00013886 | Quote Required | TBD | Petroleum-based Fluid | Rc1/8 | TAIYO Division | -5 ~+50 °C (No freezing) | 1 MPa | Rc3/8 | 1.5 MPa | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 0.0 MPa | Air-Oil converter | Nomal Close Stop Valve | AC100V 50/60Hz | 0.16 L | 2 sensors | Without flow valve | 63 mm | 40 | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | N/A | ||
| H3FG00013887 | Quote Required | TBD | Petroleum-based Fluid | Rc1/8 | TAIYO Division | -5 ~+50 °C (No freezing) | 1 MPa | Rc3/8 | 1.5 MPa | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 0.0 MPa | Air-Oil converter | Nomal Close Stop Valve | AC100V 50/60Hz | 0.16 L | 3 sensors | Without flow valve | 63 mm | 40 | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | N/A | ||
| H3FG00013888 | Quote Required | TBD | Petroleum-based Fluid | Rc1/8 | TAIYO Division | -5 ~+50 °C (No freezing) | 1 MPa | Rc3/8 | 1.5 MPa | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 0.0 MPa | Air-Oil converter | Nomal Close Stop Valve | AC100V 50/60Hz | 0.16 L | 4 sensors | Without flow valve | 63 mm | 40 | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | N/A | ||
| H3FG00013889 | Quote Required | TBD | Petroleum-based Fluid | Rc1/8 | TAIYO Division | -5 ~+50 °C (No freezing) | 1 MPa | Rc3/8 | 1.5 MPa | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 0.0 MPa | Air-Oil converter | Nomal Close Stop Valve | AC200V 50/60Hz | 0.16 L | no sensor | Without flow valve | 63 mm | 40 | no sensor | N/A | ||
| H3FG00013890 | Quote Required | TBD | Petroleum-based Fluid | Rc1/8 | TAIYO Division | -5 ~+50 °C (No freezing) | 1 MPa | Rc3/8 | 1.5 MPa | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 0.0 MPa | Air-Oil converter | Nomal Close Stop Valve | AC200V 50/60Hz | 0.16 L | 1 sensor | Without flow valve | 63 mm | 40 | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | N/A | ||
| H3FG00013891 | Quote Required | TBD | Petroleum-based Fluid | Rc1/8 | TAIYO Division | -5 ~+50 °C (No freezing) | 1 MPa | Rc3/8 | 1.5 MPa | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 0.0 MPa | Air-Oil converter | Nomal Close Stop Valve | AC200V 50/60Hz | 0.16 L | 2 sensors | Without flow valve | 63 mm | 40 | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | N/A | ||
| H3FG00013892 | Quote Required | TBD | Petroleum-based Fluid | Rc1/8 | TAIYO Division | -5 ~+50 °C (No freezing) | 1 MPa | Rc3/8 | 1.5 MPa | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 0.0 MPa | Air-Oil converter | Nomal Close Stop Valve | AC200V 50/60Hz | 0.16 L | 3 sensors | Without flow valve | 63 mm | 40 | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | N/A | ||
| H3FG00013893 | Quote Required | TBD | Petroleum-based Fluid | Rc1/8 | TAIYO Division | -5 ~+50 °C (No freezing) | 1 MPa | Rc3/8 | 1.5 MPa | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 0.0 MPa | Air-Oil converter | Nomal Close Stop Valve | AC200V 50/60Hz | 0.16 L | 4 sensors | Without flow valve | 63 mm | 40 | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | N/A | ||
| H3FG00013894 | Quote Required | TBD | Petroleum-based Fluid | Rc1/8 | TAIYO Division | -5 ~+50 °C (No freezing) | 1 MPa | Rc3/8 | 1.5 MPa | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 0.0 MPa | Air-Oil converter | Nomal Close Stop Valve | DC24V | 0.16 L | no sensor | Without flow valve | 63 mm | 40 | no sensor | N/A | ||
| H3FG00013895 | Quote Required | TBD | Petroleum-based Fluid | Rc1/8 | TAIYO Division | -5 ~+50 °C (No freezing) | 1 MPa | Rc3/8 | 1.5 MPa | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 0.0 MPa | Air-Oil converter | Nomal Close Stop Valve | DC24V | 0.16 L | 1 sensor | Without flow valve | 63 mm | 40 | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | N/A | ||
| H3FG00013896 | Quote Required | TBD | Petroleum-based Fluid | Rc1/8 | TAIYO Division | -5 ~+50 °C (No freezing) | 1 MPa | Rc3/8 | 1.5 MPa | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 0.0 MPa | Air-Oil converter | Nomal Close Stop Valve | DC24V | 0.16 L | 2 sensors | Without flow valve | 63 mm | 40 | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | N/A | ||
| H3FG00013897 | Quote Required | TBD | Petroleum-based Fluid | Rc1/8 | TAIYO Division | -5 ~+50 °C (No freezing) | 1 MPa | Rc3/8 | 1.5 MPa | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 0.0 MPa | Air-Oil converter | Nomal Close Stop Valve | DC24V | 0.16 L | 3 sensors | Without flow valve | 63 mm | 40 | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | N/A | ||
| H3FG00013898 | Quote Required | TBD | Petroleum-based Fluid | Rc1/8 | TAIYO Division | -5 ~+50 °C (No freezing) | 1 MPa | Rc3/8 | 1.5 MPa | Rc1/2 | 0.3xMain pressure+0.25MPa to 0.7MPa | 0.0 MPa | Air-Oil converter | Nomal Close Stop Valve | DC24V | 0.16 L | 4 sensors | Without flow valve | 63 mm | 40 | ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord) | N/A |