Air-Oil Unit Model:AHU2-063 (Convertor Capacity 0.16~1.6L)

Picture for category Air-Oil Unit Model:AHU2-063 (Convertor Capacity 0.16~1.6L)

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The AHU2 series is an Air-Oil Unit that converts pneumatic pressure into hydraulic control for constant speed control and arbitrary stop. Combinations such as those with flow control valves, those with throttle valves, and converters only are possible. It exerts more power when used in combination with our low-pressure hydraulic cylinder.


Markets:

・General Industry

・Machine Tools


Applications:

・General Industry

・Factory Automation

・Machine Tools


Features/Benefits:

・Because of hydraulic control, speed control is easy.

・With flow control, throttle, skip and stop valve, etc., select according to the application.

・The converter capacity is 0.16 to 20L.

・Some types are available with a switch.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceMinimum Opening PressureSupply Air Inlet Port SizeLiquid Inlet Port SizeProof PressureFor Fluid TypePilot Port SizePilot Pressure RatioDivisionOperating TemperatureMaximum Operating PressureProduct StyleAssembled Combined Valve TypeMaximum Flow Rate (lpm)Sensor ConnectionSensor typeAssembled Control Valve TypeCapacityInput VoltageOptional AccessoriesDiameter
H3FG00013779
Quote Required
TBD
0.2 MPaRc3/8Rc1/21.5 MPaPetroleum-based FluidRc1/80.3xMain pressure+0.25MPa to 0.7MPaTAIYO Division-5 ~+50 °C (No freezing)1 MPaAir-Oil converterNomal Close Skip Valve40no sensorno sensorFlow control(Meter-in control)0.16 LDC24VN/A63 mm
H3FG00013780
Quote Required
TBD
0.2 MPaRc3/8Rc1/21.5 MPaPetroleum-based FluidRc1/80.3xMain pressure+0.25MPa to 0.7MPaTAIYO Division-5 ~+50 °C (No freezing)1 MPaAir-Oil converterNomal Close Skip Valve40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)1 sensorFlow control(Meter-in control)0.16 LDC24VN/A63 mm
H3FG00013781
Quote Required
TBD
0.2 MPaRc3/8Rc1/21.5 MPaPetroleum-based FluidRc1/80.3xMain pressure+0.25MPa to 0.7MPaTAIYO Division-5 ~+50 °C (No freezing)1 MPaAir-Oil converterNomal Close Skip Valve40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)2 sensorsFlow control(Meter-in control)0.16 LDC24VN/A63 mm
H3FG00013782
Quote Required
TBD
0.2 MPaRc3/8Rc1/21.5 MPaPetroleum-based FluidRc1/80.3xMain pressure+0.25MPa to 0.7MPaTAIYO Division-5 ~+50 °C (No freezing)1 MPaAir-Oil converterNomal Close Skip Valve40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)3 sensorsFlow control(Meter-in control)0.16 LDC24VN/A63 mm
H3FG00013783
Quote Required
TBD
0.2 MPaRc3/8Rc1/21.5 MPaPetroleum-based FluidRc1/80.3xMain pressure+0.25MPa to 0.7MPaTAIYO Division-5 ~+50 °C (No freezing)1 MPaAir-Oil converterNomal Close Skip Valve40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)4 sensorsFlow control(Meter-in control)0.16 LDC24VN/A63 mm
H3FG00013784
Quote Required
TBD
0.2 MPaRc3/8Rc1/21.5 MPaPetroleum-based FluidRc1/80.3xMain pressure+0.25MPa to 0.7MPaTAIYO Division-5 ~+50 °C (No freezing)1 MPaAir-Oil converterNormal Open Skip Valve40no sensorno sensorFlow control(Meter-out control)0.16 LAC100V 50/60HzN/A63 mm
H3FG00013785
Quote Required
TBD
0.2 MPaRc3/8Rc1/21.5 MPaPetroleum-based FluidRc1/80.3xMain pressure+0.25MPa to 0.7MPaTAIYO Division-5 ~+50 °C (No freezing)1 MPaAir-Oil converterNormal Open Skip Valve40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)1 sensorFlow control(Meter-out control)0.16 LAC100V 50/60HzN/A63 mm
H3FG00013786
Quote Required
TBD
0.2 MPaRc3/8Rc1/21.5 MPaPetroleum-based FluidRc1/80.3xMain pressure+0.25MPa to 0.7MPaTAIYO Division-5 ~+50 °C (No freezing)1 MPaAir-Oil converterNormal Open Skip Valve40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)2 sensorsFlow control(Meter-out control)0.16 LAC100V 50/60HzN/A63 mm
H3FG00013787
Quote Required
TBD
0.2 MPaRc3/8Rc1/21.5 MPaPetroleum-based FluidRc1/80.3xMain pressure+0.25MPa to 0.7MPaTAIYO Division-5 ~+50 °C (No freezing)1 MPaAir-Oil converterNormal Open Skip Valve40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)3 sensorsFlow control(Meter-out control)0.16 LAC100V 50/60HzN/A63 mm
H3FG00013788
Quote Required
TBD
0.2 MPaRc3/8Rc1/21.5 MPaPetroleum-based FluidRc1/80.3xMain pressure+0.25MPa to 0.7MPaTAIYO Division-5 ~+50 °C (No freezing)1 MPaAir-Oil converterNormal Open Skip Valve40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)4 sensorsFlow control(Meter-out control)0.16 LAC100V 50/60HzN/A63 mm
H3FG00013789
Quote Required
TBD
0.2 MPaRc3/8Rc1/21.5 MPaPetroleum-based FluidRc1/80.3xMain pressure+0.25MPa to 0.7MPaTAIYO Division-5 ~+50 °C (No freezing)1 MPaAir-Oil converterNormal Open Skip Valve40no sensorno sensorFlow control(Meter-out control)0.16 LAC200V 50/60HzN/A63 mm
H3FG00013790
Quote Required
TBD
0.2 MPaRc3/8Rc1/21.5 MPaPetroleum-based FluidRc1/80.3xMain pressure+0.25MPa to 0.7MPaTAIYO Division-5 ~+50 °C (No freezing)1 MPaAir-Oil converterNormal Open Skip Valve40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)1 sensorFlow control(Meter-out control)0.16 LAC200V 50/60HzN/A63 mm
H3FG00013791
Quote Required
TBD
0.2 MPaRc3/8Rc1/21.5 MPaPetroleum-based FluidRc1/80.3xMain pressure+0.25MPa to 0.7MPaTAIYO Division-5 ~+50 °C (No freezing)1 MPaAir-Oil converterNormal Open Skip Valve40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)2 sensorsFlow control(Meter-out control)0.16 LAC200V 50/60HzN/A63 mm
H3FG00013792
Quote Required
TBD
0.2 MPaRc3/8Rc1/21.5 MPaPetroleum-based FluidRc1/80.3xMain pressure+0.25MPa to 0.7MPaTAIYO Division-5 ~+50 °C (No freezing)1 MPaAir-Oil converterNormal Open Skip Valve40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)3 sensorsFlow control(Meter-out control)0.16 LAC200V 50/60HzN/A63 mm
H3FG00013793
Quote Required
TBD
0.2 MPaRc3/8Rc1/21.5 MPaPetroleum-based FluidRc1/80.3xMain pressure+0.25MPa to 0.7MPaTAIYO Division-5 ~+50 °C (No freezing)1 MPaAir-Oil converterNormal Open Skip Valve40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)4 sensorsFlow control(Meter-out control)0.16 LAC200V 50/60HzN/A63 mm
H3FG00013794
Quote Required
TBD
0.2 MPaRc3/8Rc1/21.5 MPaPetroleum-based FluidRc1/80.3xMain pressure+0.25MPa to 0.7MPaTAIYO Division-5 ~+50 °C (No freezing)1 MPaAir-Oil converterNormal Open Skip Valve40no sensorno sensorFlow control(Meter-out control)0.16 LDC24VN/A63 mm
H3FG00013795
Quote Required
TBD
0.2 MPaRc3/8Rc1/21.5 MPaPetroleum-based FluidRc1/80.3xMain pressure+0.25MPa to 0.7MPaTAIYO Division-5 ~+50 °C (No freezing)1 MPaAir-Oil converterNormal Open Skip Valve40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)1 sensorFlow control(Meter-out control)0.16 LDC24VN/A63 mm
H3FG00013796
Quote Required
TBD
0.2 MPaRc3/8Rc1/21.5 MPaPetroleum-based FluidRc1/80.3xMain pressure+0.25MPa to 0.7MPaTAIYO Division-5 ~+50 °C (No freezing)1 MPaAir-Oil converterNormal Open Skip Valve40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)2 sensorsFlow control(Meter-out control)0.16 LDC24VN/A63 mm
H3FG00013797
Quote Required
TBD
0.2 MPaRc3/8Rc1/21.5 MPaPetroleum-based FluidRc1/80.3xMain pressure+0.25MPa to 0.7MPaTAIYO Division-5 ~+50 °C (No freezing)1 MPaAir-Oil converterNormal Open Skip Valve40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)3 sensorsFlow control(Meter-out control)0.16 LDC24VN/A63 mm
H3FG00013798
Quote Required
TBD
0.2 MPaRc3/8Rc1/21.5 MPaPetroleum-based FluidRc1/80.3xMain pressure+0.25MPa to 0.7MPaTAIYO Division-5 ~+50 °C (No freezing)1 MPaAir-Oil converterNormal Open Skip Valve40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)4 sensorsFlow control(Meter-out control)0.16 LDC24VN/A63 mm