Air-Oil Unit Model:AHU2-063 (Convertor Capacity 0.16~1.6L)

Picture for category Air-Oil Unit Model:AHU2-063 (Convertor Capacity 0.16~1.6L)

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The AHU2 series is an Air-Oil Unit that converts pneumatic pressure into hydraulic control for constant speed control and arbitrary stop. Combinations such as those with flow control valves, those with throttle valves, and converters only are possible. It exerts more power when used in combination with our low-pressure hydraulic cylinder.


Markets:

・General Industry

・Machine Tools


Applications:

・General Industry

・Factory Automation

・Machine Tools


Features/Benefits:

・Because of hydraulic control, speed control is easy.

・With flow control, throttle, skip and stop valve, etc., select according to the application.

・The converter capacity is 0.16 to 20L.

・Some types are available with a switch.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePricePilot Port SizeMinimum Opening PressureFor Fluid TypeLiquid Inlet Port SizeProof PressureSupply Air Inlet Port SizeProduct StyleMaximum Operating PressureOperating TemperatureDivisionPilot Pressure RatioCapacitySensor typeMaximum Flow Rate (lpm)Sensor ConnectionInput VoltageDiameterOptional AccessoriesAssembled Combined Valve TypeAssembled Control Valve Type
H3FG00014959
Quote Required
TBD
Rc1/80.05 MPaPetroleum-based FluidRc1/21.5 MPaRc3/8Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPa0.4 Lno sensor40no sensorAC200V 50/60Hz63 mmN/ANormal Open Skip ValveThrottle control(Meter-in control)
H3FG00014960
Quote Required
TBD
Rc1/80.05 MPaPetroleum-based FluidRc1/21.5 MPaRc3/8Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPa0.4 L1 sensor40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)AC200V 50/60Hz63 mmN/ANormal Open Skip ValveThrottle control(Meter-in control)
H3FG00014961
Quote Required
TBD
Rc1/80.05 MPaPetroleum-based FluidRc1/21.5 MPaRc3/8Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPa0.4 L2 sensors40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)AC200V 50/60Hz63 mmN/ANormal Open Skip ValveThrottle control(Meter-in control)
H3FG00014962
Quote Required
TBD
Rc1/80.05 MPaPetroleum-based FluidRc1/21.5 MPaRc3/8Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPa0.4 L3 sensors40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)AC200V 50/60Hz63 mmN/ANormal Open Skip ValveThrottle control(Meter-in control)
H3FG00014963
Quote Required
TBD
Rc1/80.05 MPaPetroleum-based FluidRc1/21.5 MPaRc3/8Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPa0.4 L4 sensors40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)AC200V 50/60Hz63 mmN/ANormal Open Skip ValveThrottle control(Meter-in control)
H3FG00014964
Quote Required
TBD
Rc1/80.05 MPaPetroleum-based FluidRc1/21.5 MPaRc3/8Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPa0.4 Lno sensor40no sensorDC24V63 mmN/ANormal Open Skip ValveThrottle control(Meter-in control)
H3FG00014965
Quote Required
TBD
Rc1/80.05 MPaPetroleum-based FluidRc1/21.5 MPaRc3/8Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPa0.4 L1 sensor40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)DC24V63 mmN/ANormal Open Skip ValveThrottle control(Meter-in control)
H3FG00014966
Quote Required
TBD
Rc1/80.05 MPaPetroleum-based FluidRc1/21.5 MPaRc3/8Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPa0.4 L2 sensors40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)DC24V63 mmN/ANormal Open Skip ValveThrottle control(Meter-in control)
H3FG00014967
Quote Required
TBD
Rc1/80.05 MPaPetroleum-based FluidRc1/21.5 MPaRc3/8Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPa0.4 L3 sensors40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)DC24V63 mmN/ANormal Open Skip ValveThrottle control(Meter-in control)
H3FG00014968
Quote Required
TBD
Rc1/80.05 MPaPetroleum-based FluidRc1/21.5 MPaRc3/8Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPa0.4 L4 sensors40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)DC24V63 mmN/ANormal Open Skip ValveThrottle control(Meter-in control)
H3FG00014969
Quote Required
TBD
Rc1/80.05 MPaPetroleum-based FluidRc1/21.5 MPaRc3/8Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPa0.4 Lno sensor40no sensorn/a63 mmN/AWithout valveThrottle control(Meter-out control)
H3FG00014970
Quote Required
TBD
Rc1/80.05 MPaPetroleum-based FluidRc1/21.5 MPaRc3/8Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPa0.4 L1 sensor40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)n/a63 mmN/AWithout valveThrottle control(Meter-out control)
H3FG00014971
Quote Required
TBD
Rc1/80.05 MPaPetroleum-based FluidRc1/21.5 MPaRc3/8Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPa0.4 L2 sensors40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)n/a63 mmN/AWithout valveThrottle control(Meter-out control)
H3FG00014972
Quote Required
TBD
Rc1/80.05 MPaPetroleum-based FluidRc1/21.5 MPaRc3/8Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPa0.4 L3 sensors40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)n/a63 mmN/AWithout valveThrottle control(Meter-out control)
H3FG00014973
Quote Required
TBD
Rc1/80.05 MPaPetroleum-based FluidRc1/21.5 MPaRc3/8Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPa0.4 L4 sensors40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)n/a63 mmN/AWithout valveThrottle control(Meter-out control)
H3FG00014974
Quote Required
TBD
Rc1/80.05 MPaPetroleum-based FluidRc1/21.5 MPaRc3/8Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPa0.4 Lno sensor40no sensorn/a63 mmN/AWithout valveThrottle control(Meter-in control)
H3FG00014975
Quote Required
TBD
Rc1/80.05 MPaPetroleum-based FluidRc1/21.5 MPaRc3/8Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPa0.4 L1 sensor40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)n/a63 mmN/AWithout valveThrottle control(Meter-in control)
H3FG00014976
Quote Required
TBD
Rc1/80.05 MPaPetroleum-based FluidRc1/21.5 MPaRc3/8Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPa0.4 L2 sensors40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)n/a63 mmN/AWithout valveThrottle control(Meter-in control)
H3FG00014977
Quote Required
TBD
Rc1/80.05 MPaPetroleum-based FluidRc1/21.5 MPaRc3/8Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPa0.4 L3 sensors40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)n/a63 mmN/AWithout valveThrottle control(Meter-in control)
H3FG00014978
Quote Required
TBD
Rc1/80.05 MPaPetroleum-based FluidRc1/21.5 MPaRc3/8Air-Oil converter1 MPa-5 ~+50 °C (No freezing)TAIYO Division0.3xMain pressure+0.25MPa to 0.7MPa0.4 L4 sensors40ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)n/a63 mmN/AWithout valveThrottle control(Meter-in control)