Air-Oil Unit Model:AHU2-063 (Convertor Capacity 0.16~1.6L)

Picture for category Air-Oil Unit Model:AHU2-063 (Convertor Capacity 0.16~1.6L)

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The AHU2 series is an Air-Oil Unit that converts pneumatic pressure into hydraulic control for constant speed control and arbitrary stop. Combinations such as those with flow control valves, those with throttle valves, and converters only are possible. It exerts more power when used in combination with our low-pressure hydraulic cylinder.


Markets:

・General Industry

・Machine Tools


Applications:

・General Industry

・Factory Automation

・Machine Tools


Features/Benefits:

・Because of hydraulic control, speed control is easy.

・With flow control, throttle, skip and stop valve, etc., select according to the application.

・The converter capacity is 0.16 to 20L.

・Some types are available with a switch.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceMaximum Operating PressureDivisionOperating TemperatureSupply Air Inlet Port SizePilot Pressure RatioMinimum Opening PressureProduct StyleProof PressureLiquid Inlet Port SizeFor Fluid TypePilot Port SizeDiameterAssembled Control Valve TypeOptional AccessoriesSensor ConnectionMaximum Flow Rate (lpm)CapacityAssembled Combined Valve TypeSensor typeInput Voltage
H3FG00014319
Quote Required
TBD
1 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc3/80.3xMain pressure+0.25MPa to 0.7MPa0.2 MPaAir-Oil converter1.5 MPaRc1/2Petroleum-based FluidRc1/863 mmFlow control(Meter-out control)N/Ano sensor400.25 LNormal Open Stop Valveno sensorAC200V 50/60Hz
H3FG00014320
Quote Required
TBD
1 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc3/80.3xMain pressure+0.25MPa to 0.7MPa0.2 MPaAir-Oil converter1.5 MPaRc1/2Petroleum-based FluidRc1/863 mmFlow control(Meter-out control)N/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)400.25 LNormal Open Stop Valve1 sensorAC200V 50/60Hz
H3FG00014321
Quote Required
TBD
1 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc3/80.3xMain pressure+0.25MPa to 0.7MPa0.2 MPaAir-Oil converter1.5 MPaRc1/2Petroleum-based FluidRc1/863 mmFlow control(Meter-out control)N/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)400.25 LNormal Open Stop Valve2 sensorsAC200V 50/60Hz
H3FG00014322
Quote Required
TBD
1 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc3/80.3xMain pressure+0.25MPa to 0.7MPa0.2 MPaAir-Oil converter1.5 MPaRc1/2Petroleum-based FluidRc1/863 mmFlow control(Meter-out control)N/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)400.25 LNormal Open Stop Valve3 sensorsAC200V 50/60Hz
H3FG00014323
Quote Required
TBD
1 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc3/80.3xMain pressure+0.25MPa to 0.7MPa0.2 MPaAir-Oil converter1.5 MPaRc1/2Petroleum-based FluidRc1/863 mmFlow control(Meter-out control)N/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)400.25 LNormal Open Stop Valve4 sensorsAC200V 50/60Hz
H3FG00014324
Quote Required
TBD
1 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc3/80.3xMain pressure+0.25MPa to 0.7MPa0.2 MPaAir-Oil converter1.5 MPaRc1/2Petroleum-based FluidRc1/863 mmFlow control(Meter-out control)N/Ano sensor400.25 LNormal Open Stop Valveno sensorDC24V
H3FG00014325
Quote Required
TBD
1 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc3/80.3xMain pressure+0.25MPa to 0.7MPa0.2 MPaAir-Oil converter1.5 MPaRc1/2Petroleum-based FluidRc1/863 mmFlow control(Meter-out control)N/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)400.25 LNormal Open Stop Valve1 sensorDC24V
H3FG00014326
Quote Required
TBD
1 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc3/80.3xMain pressure+0.25MPa to 0.7MPa0.2 MPaAir-Oil converter1.5 MPaRc1/2Petroleum-based FluidRc1/863 mmFlow control(Meter-out control)N/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)400.25 LNormal Open Stop Valve2 sensorsDC24V
H3FG00014327
Quote Required
TBD
1 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc3/80.3xMain pressure+0.25MPa to 0.7MPa0.2 MPaAir-Oil converter1.5 MPaRc1/2Petroleum-based FluidRc1/863 mmFlow control(Meter-out control)N/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)400.25 LNormal Open Stop Valve3 sensorsDC24V
H3FG00014328
Quote Required
TBD
1 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc3/80.3xMain pressure+0.25MPa to 0.7MPa0.2 MPaAir-Oil converter1.5 MPaRc1/2Petroleum-based FluidRc1/863 mmFlow control(Meter-out control)N/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)400.25 LNormal Open Stop Valve4 sensorsDC24V
H3FG00014329
Quote Required
TBD
1 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc3/80.3xMain pressure+0.25MPa to 0.7MPa0.2 MPaAir-Oil converter1.5 MPaRc1/2Petroleum-based FluidRc1/863 mmFlow control(Meter-in control)N/Ano sensor400.25 LNormal Open Stop Valveno sensorAC100V 50/60Hz
H3FG00014330
Quote Required
TBD
1 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc3/80.3xMain pressure+0.25MPa to 0.7MPa0.2 MPaAir-Oil converter1.5 MPaRc1/2Petroleum-based FluidRc1/863 mmFlow control(Meter-in control)N/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)400.25 LNormal Open Stop Valve1 sensorAC100V 50/60Hz
H3FG00014331
Quote Required
TBD
1 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc3/80.3xMain pressure+0.25MPa to 0.7MPa0.2 MPaAir-Oil converter1.5 MPaRc1/2Petroleum-based FluidRc1/863 mmFlow control(Meter-in control)N/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)400.25 LNormal Open Stop Valve2 sensorsAC100V 50/60Hz
H3FG00014332
Quote Required
TBD
1 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc3/80.3xMain pressure+0.25MPa to 0.7MPa0.2 MPaAir-Oil converter1.5 MPaRc1/2Petroleum-based FluidRc1/863 mmFlow control(Meter-in control)N/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)400.25 LNormal Open Stop Valve3 sensorsAC100V 50/60Hz
H3FG00014333
Quote Required
TBD
1 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc3/80.3xMain pressure+0.25MPa to 0.7MPa0.2 MPaAir-Oil converter1.5 MPaRc1/2Petroleum-based FluidRc1/863 mmFlow control(Meter-in control)N/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)400.25 LNormal Open Stop Valve4 sensorsAC100V 50/60Hz
H3FG00014334
Quote Required
TBD
1 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc3/80.3xMain pressure+0.25MPa to 0.7MPa0.2 MPaAir-Oil converter1.5 MPaRc1/2Petroleum-based FluidRc1/863 mmFlow control(Meter-in control)N/Ano sensor400.25 LNormal Open Stop Valveno sensorAC200V 50/60Hz
H3FG00014335
Quote Required
TBD
1 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc3/80.3xMain pressure+0.25MPa to 0.7MPa0.2 MPaAir-Oil converter1.5 MPaRc1/2Petroleum-based FluidRc1/863 mmFlow control(Meter-in control)N/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)400.25 LNormal Open Stop Valve1 sensorAC200V 50/60Hz
H3FG00014336
Quote Required
TBD
1 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc3/80.3xMain pressure+0.25MPa to 0.7MPa0.2 MPaAir-Oil converter1.5 MPaRc1/2Petroleum-based FluidRc1/863 mmFlow control(Meter-in control)N/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)400.25 LNormal Open Stop Valve2 sensorsAC200V 50/60Hz
H3FG00014337
Quote Required
TBD
1 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc3/80.3xMain pressure+0.25MPa to 0.7MPa0.2 MPaAir-Oil converter1.5 MPaRc1/2Petroleum-based FluidRc1/863 mmFlow control(Meter-in control)N/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)400.25 LNormal Open Stop Valve3 sensorsAC200V 50/60Hz
H3FG00014338
Quote Required
TBD
1 MPaTAIYO Division-5 ~+50 °C (No freezing)Rc3/80.3xMain pressure+0.25MPa to 0.7MPa0.2 MPaAir-Oil converter1.5 MPaRc1/2Petroleum-based FluidRc1/863 mmFlow control(Meter-in control)N/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)400.25 LNormal Open Stop Valve4 sensorsAC200V 50/60Hz