• Availability & Price
  • Search SKU
Filter by attributes
  • Assembled Combined Valve Type
  • Assembled Control Valve Type
  • Capacity
  • Diameter
  • Input Voltage
  • Maximum Flow Rate (lpm)
  • Optional Accessories
  • Sensor Connection
  • Sensor type
More Filters...
Filter by manufacturer
Manufacturers

Air-Oil Unit Model:AHU2-063 (Convertor Capacity 0.16~1.6L)

Picture for category Air-Oil Unit Model:AHU2-063 (Convertor Capacity 0.16~1.6L)

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The AHU2 series is an Air-Oil Unit that converts pneumatic pressure into hydraulic control for constant speed control and arbitrary stop. Combinations such as those with flow control valves, those with throttle valves, and converters only are possible. It exerts more power when used in combination with our low-pressure hydraulic cylinder.


Markets:

・General Industry

・Machine Tools


Applications:

・General Industry

・Factory Automation

・Machine Tools


Features/Benefits:

・Because of hydraulic control, speed control is easy.

・With flow control, throttle, skip and stop valve, etc., select according to the application.

・The converter capacity is 0.16 to 20L.

・Some types are available with a switch.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceProduct StyleOperating TemperatureDivisionMaximum Operating PressurePilot Pressure RatioMinimum Opening PressurePilot Port SizeFor Fluid TypeSupply Air Inlet Port SizeProof PressureLiquid Inlet Port SizeSensor ConnectionMaximum Flow Rate (lpm)Optional AccessoriesAssembled Combined Valve TypeDiameterAssembled Control Valve TypeInput VoltageSensor typeCapacity
H3FG00016219
Quote Required
TBD
Air-Oil converter-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.05 MPaRc1/8Petroleum-based FluidRc3/81.5 MPaRc1/2no sensor40N/ANomal Close Skip Valve/Nomal Close Stop Valve63 mmThrottle control(Meter-in control)AC200V 50/60Hzno sensor1.6 L
H3FG00016220
Quote Required
TBD
Air-Oil converter-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.05 MPaRc1/8Petroleum-based FluidRc3/81.5 MPaRc1/2ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40N/ANomal Close Skip Valve/Nomal Close Stop Valve63 mmThrottle control(Meter-in control)AC200V 50/60Hz1 sensor1.6 L
H3FG00016221
Quote Required
TBD
Air-Oil converter-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.05 MPaRc1/8Petroleum-based FluidRc3/81.5 MPaRc1/2ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40N/ANomal Close Skip Valve/Nomal Close Stop Valve63 mmThrottle control(Meter-in control)AC200V 50/60Hz2 sensors1.6 L
H3FG00016222
Quote Required
TBD
Air-Oil converter-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.05 MPaRc1/8Petroleum-based FluidRc3/81.5 MPaRc1/2ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40N/ANomal Close Skip Valve/Nomal Close Stop Valve63 mmThrottle control(Meter-in control)AC200V 50/60Hz3 sensors1.6 L
H3FG00016223
Quote Required
TBD
Air-Oil converter-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.05 MPaRc1/8Petroleum-based FluidRc3/81.5 MPaRc1/2ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40N/ANomal Close Skip Valve/Nomal Close Stop Valve63 mmThrottle control(Meter-in control)AC200V 50/60Hz4 sensors1.6 L
H3FG00016224
Quote Required
TBD
Air-Oil converter-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.05 MPaRc1/8Petroleum-based FluidRc3/81.5 MPaRc1/2no sensor40N/ANomal Close Skip Valve/Nomal Close Stop Valve63 mmThrottle control(Meter-in control)DC24Vno sensor1.6 L
H3FG00016225
Quote Required
TBD
Air-Oil converter-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.05 MPaRc1/8Petroleum-based FluidRc3/81.5 MPaRc1/2ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40N/ANomal Close Skip Valve/Nomal Close Stop Valve63 mmThrottle control(Meter-in control)DC24V1 sensor1.6 L
H3FG00016226
Quote Required
TBD
Air-Oil converter-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.05 MPaRc1/8Petroleum-based FluidRc3/81.5 MPaRc1/2ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40N/ANomal Close Skip Valve/Nomal Close Stop Valve63 mmThrottle control(Meter-in control)DC24V2 sensors1.6 L
H3FG00016227
Quote Required
TBD
Air-Oil converter-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.05 MPaRc1/8Petroleum-based FluidRc3/81.5 MPaRc1/2ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40N/ANomal Close Skip Valve/Nomal Close Stop Valve63 mmThrottle control(Meter-in control)DC24V3 sensors1.6 L
H3FG00016228
Quote Required
TBD
Air-Oil converter-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.05 MPaRc1/8Petroleum-based FluidRc3/81.5 MPaRc1/2ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40N/ANomal Close Skip Valve/Nomal Close Stop Valve63 mmThrottle control(Meter-in control)DC24V4 sensors1.6 L
H3FG00016229
Quote Required
TBD
Air-Oil converter-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.05 MPaRc1/8Petroleum-based FluidRc3/81.5 MPaRc1/2no sensor40N/ANormal Open Skip Valve/Nomal Close Stop Valve63 mmThrottle control(Meter-out control)AC100V 50/60Hzno sensor1.6 L
H3FG00016230
Quote Required
TBD
Air-Oil converter-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.05 MPaRc1/8Petroleum-based FluidRc3/81.5 MPaRc1/2ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40N/ANormal Open Skip Valve/Nomal Close Stop Valve63 mmThrottle control(Meter-out control)AC100V 50/60Hz1 sensor1.6 L
H3FG00016231
Quote Required
TBD
Air-Oil converter-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.05 MPaRc1/8Petroleum-based FluidRc3/81.5 MPaRc1/2ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40N/ANormal Open Skip Valve/Nomal Close Stop Valve63 mmThrottle control(Meter-out control)AC100V 50/60Hz2 sensors1.6 L
H3FG00016232
Quote Required
TBD
Air-Oil converter-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.05 MPaRc1/8Petroleum-based FluidRc3/81.5 MPaRc1/2ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40N/ANormal Open Skip Valve/Nomal Close Stop Valve63 mmThrottle control(Meter-out control)AC100V 50/60Hz3 sensors1.6 L
H3FG00016233
Quote Required
TBD
Air-Oil converter-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.05 MPaRc1/8Petroleum-based FluidRc3/81.5 MPaRc1/2ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40N/ANormal Open Skip Valve/Nomal Close Stop Valve63 mmThrottle control(Meter-out control)AC100V 50/60Hz4 sensors1.6 L
H3FG00016234
Quote Required
TBD
Air-Oil converter-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.05 MPaRc1/8Petroleum-based FluidRc3/81.5 MPaRc1/2no sensor40N/ANormal Open Skip Valve/Nomal Close Stop Valve63 mmThrottle control(Meter-out control)AC200V 50/60Hzno sensor1.6 L
H3FG00016235
Quote Required
TBD
Air-Oil converter-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.05 MPaRc1/8Petroleum-based FluidRc3/81.5 MPaRc1/2ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40N/ANormal Open Skip Valve/Nomal Close Stop Valve63 mmThrottle control(Meter-out control)AC200V 50/60Hz1 sensor1.6 L
H3FG00016236
Quote Required
TBD
Air-Oil converter-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.05 MPaRc1/8Petroleum-based FluidRc3/81.5 MPaRc1/2ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40N/ANormal Open Skip Valve/Nomal Close Stop Valve63 mmThrottle control(Meter-out control)AC200V 50/60Hz2 sensors1.6 L
H3FG00016237
Quote Required
TBD
Air-Oil converter-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.05 MPaRc1/8Petroleum-based FluidRc3/81.5 MPaRc1/2ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40N/ANormal Open Skip Valve/Nomal Close Stop Valve63 mmThrottle control(Meter-out control)AC200V 50/60Hz3 sensors1.6 L
H3FG00016238
Quote Required
TBD
Air-Oil converter-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.3xMain pressure+0.25MPa to 0.7MPa0.05 MPaRc1/8Petroleum-based FluidRc3/81.5 MPaRc1/2ZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40N/ANormal Open Skip Valve/Nomal Close Stop Valve63 mmThrottle control(Meter-out control)AC200V 50/60Hz4 sensors1.6 L