• Availability & Price
  • Search SKU
Filter by attributes
  • Assembled Combined Valve Type
  • Assembled Control Valve Type
  • Capacity
  • Diameter
  • Input Voltage
  • Maximum Flow Rate (lpm)
  • Optional Accessories
  • Sensor Connection
  • Sensor type
More Filters...
Filter by manufacturer
Manufacturers

Air-Oil Unit Model:AHU2-063 (Convertor Capacity 0.16~1.6L)

Picture for category Air-Oil Unit Model:AHU2-063 (Convertor Capacity 0.16~1.6L)

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The AHU2 series is an Air-Oil Unit that converts pneumatic pressure into hydraulic control for constant speed control and arbitrary stop. Combinations such as those with flow control valves, those with throttle valves, and converters only are possible. It exerts more power when used in combination with our low-pressure hydraulic cylinder.


Markets:

・General Industry

・Machine Tools


Applications:

・General Industry

・Factory Automation

・Machine Tools


Features/Benefits:

・Because of hydraulic control, speed control is easy.

・With flow control, throttle, skip and stop valve, etc., select according to the application.

・The converter capacity is 0.16 to 20L.

・Some types are available with a switch.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePricePilot Pressure RatioFor Fluid TypeSupply Air Inlet Port SizeProof PressureLiquid Inlet Port SizeOperating TemperatureDivisionMaximum Operating PressureMinimum Opening PressurePilot Port SizeProduct StyleAssembled Control Valve TypeSensor typeInput VoltageDiameterSensor ConnectionMaximum Flow Rate (lpm)CapacityOptional AccessoriesAssembled Combined Valve Type
H3FG00015919
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaPetroleum-based FluidRc3/81.5 MPaRc1/2-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.05 MPaRc1/8Air-Oil converterThrottle control(Meter-in control)no sensorAC200V 50/60Hz63 mmno sensor401 LN/ANomal Close Stop Valve
H3FG00015920
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaPetroleum-based FluidRc3/81.5 MPaRc1/2-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.05 MPaRc1/8Air-Oil converterThrottle control(Meter-in control)1 sensorAC200V 50/60Hz63 mmZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)401 LN/ANomal Close Stop Valve
H3FG00015921
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaPetroleum-based FluidRc3/81.5 MPaRc1/2-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.05 MPaRc1/8Air-Oil converterThrottle control(Meter-in control)2 sensorsAC200V 50/60Hz63 mmZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)401 LN/ANomal Close Stop Valve
H3FG00015922
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaPetroleum-based FluidRc3/81.5 MPaRc1/2-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.05 MPaRc1/8Air-Oil converterThrottle control(Meter-in control)3 sensorsAC200V 50/60Hz63 mmZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)401 LN/ANomal Close Stop Valve
H3FG00015923
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaPetroleum-based FluidRc3/81.5 MPaRc1/2-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.05 MPaRc1/8Air-Oil converterThrottle control(Meter-in control)4 sensorsAC200V 50/60Hz63 mmZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)401 LN/ANomal Close Stop Valve
H3FG00015924
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaPetroleum-based FluidRc3/81.5 MPaRc1/2-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.05 MPaRc1/8Air-Oil converterThrottle control(Meter-in control)no sensorDC24V63 mmno sensor401 LN/ANomal Close Stop Valve
H3FG00015925
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaPetroleum-based FluidRc3/81.5 MPaRc1/2-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.05 MPaRc1/8Air-Oil converterThrottle control(Meter-in control)1 sensorDC24V63 mmZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)401 LN/ANomal Close Stop Valve
H3FG00015926
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaPetroleum-based FluidRc3/81.5 MPaRc1/2-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.05 MPaRc1/8Air-Oil converterThrottle control(Meter-in control)2 sensorsDC24V63 mmZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)401 LN/ANomal Close Stop Valve
H3FG00015927
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaPetroleum-based FluidRc3/81.5 MPaRc1/2-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.05 MPaRc1/8Air-Oil converterThrottle control(Meter-in control)3 sensorsDC24V63 mmZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)401 LN/ANomal Close Stop Valve
H3FG00015928
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaPetroleum-based FluidRc3/81.5 MPaRc1/2-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.05 MPaRc1/8Air-Oil converterThrottle control(Meter-in control)4 sensorsDC24V63 mmZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)401 LN/ANomal Close Stop Valve
H3FG00015929
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaPetroleum-based FluidRc3/81.5 MPaRc1/2-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.05 MPaRc1/8Air-Oil converterThrottle control(Meter-out control)no sensorAC100V 50/60Hz63 mmno sensor401 LN/ANormal Open Stop Valve
H3FG00015930
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaPetroleum-based FluidRc3/81.5 MPaRc1/2-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.05 MPaRc1/8Air-Oil converterThrottle control(Meter-out control)1 sensorAC100V 50/60Hz63 mmZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)401 LN/ANormal Open Stop Valve
H3FG00015931
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaPetroleum-based FluidRc3/81.5 MPaRc1/2-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.05 MPaRc1/8Air-Oil converterThrottle control(Meter-out control)2 sensorsAC100V 50/60Hz63 mmZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)401 LN/ANormal Open Stop Valve
H3FG00015932
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaPetroleum-based FluidRc3/81.5 MPaRc1/2-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.05 MPaRc1/8Air-Oil converterThrottle control(Meter-out control)3 sensorsAC100V 50/60Hz63 mmZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)401 LN/ANormal Open Stop Valve
H3FG00015933
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaPetroleum-based FluidRc3/81.5 MPaRc1/2-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.05 MPaRc1/8Air-Oil converterThrottle control(Meter-out control)4 sensorsAC100V 50/60Hz63 mmZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)401 LN/ANormal Open Stop Valve
H3FG00015934
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaPetroleum-based FluidRc3/81.5 MPaRc1/2-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.05 MPaRc1/8Air-Oil converterThrottle control(Meter-out control)no sensorAC200V 50/60Hz63 mmno sensor401 LN/ANormal Open Stop Valve
H3FG00015935
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaPetroleum-based FluidRc3/81.5 MPaRc1/2-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.05 MPaRc1/8Air-Oil converterThrottle control(Meter-out control)1 sensorAC200V 50/60Hz63 mmZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)401 LN/ANormal Open Stop Valve
H3FG00015936
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaPetroleum-based FluidRc3/81.5 MPaRc1/2-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.05 MPaRc1/8Air-Oil converterThrottle control(Meter-out control)2 sensorsAC200V 50/60Hz63 mmZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)401 LN/ANormal Open Stop Valve
H3FG00015937
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaPetroleum-based FluidRc3/81.5 MPaRc1/2-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.05 MPaRc1/8Air-Oil converterThrottle control(Meter-out control)3 sensorsAC200V 50/60Hz63 mmZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)401 LN/ANormal Open Stop Valve
H3FG00015938
Quote Required
TBD
0.3xMain pressure+0.25MPa to 0.7MPaPetroleum-based FluidRc3/81.5 MPaRc1/2-5 ~+50 °C (No freezing)TAIYO Division1 MPa0.05 MPaRc1/8Air-Oil converterThrottle control(Meter-out control)4 sensorsAC200V 50/60Hz63 mmZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)401 LN/ANormal Open Stop Valve