• Availability & Price
  • Search SKU
Filter by attributes
  • Assembled Combined Valve Type
  • Assembled Control Valve Type
  • Capacity
  • Diameter
  • Input Voltage
  • Maximum Flow Rate (lpm)
  • Optional Accessories
  • Sensor Connection
  • Sensor type
More Filters...
Filter by manufacturer
Manufacturers

Air-Oil Unit Model:AHU2-063 (Convertor Capacity 0.16~1.6L)

Picture for category Air-Oil Unit Model:AHU2-063 (Convertor Capacity 0.16~1.6L)

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The AHU2 series is an Air-Oil Unit that converts pneumatic pressure into hydraulic control for constant speed control and arbitrary stop. Combinations such as those with flow control valves, those with throttle valves, and converters only are possible. It exerts more power when used in combination with our low-pressure hydraulic cylinder.


Markets:

・General Industry

・Machine Tools


Applications:

・General Industry

・Factory Automation

・Machine Tools


Features/Benefits:

・Because of hydraulic control, speed control is easy.

・With flow control, throttle, skip and stop valve, etc., select according to the application.

・The converter capacity is 0.16 to 20L.

・Some types are available with a switch.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceOperating TemperatureSupply Air Inlet Port SizeMaximum Operating PressureDivisionPilot Port SizeProof PressureLiquid Inlet Port SizeFor Fluid TypeProduct StyleMinimum Opening PressurePilot Pressure RatioInput VoltageAssembled Combined Valve TypeSensor typeCapacityOptional AccessoriesSensor ConnectionMaximum Flow Rate (lpm)Assembled Control Valve TypeDiameter
H3FG00014779
Quote Required
TBD
-5 ~+50 °C (No freezing)Rc3/81 MPaTAIYO DivisionRc1/81.5 MPaRc1/2Petroleum-based FluidAir-Oil converter0.2 MPa0.3xMain pressure+0.25MPa to 0.7MPaAC200V 50/60HzNormal Open Stop Valveno sensor0.4 LN/Ano sensor40Flow control(Meter-out control)63 mm
H3FG00014780
Quote Required
TBD
-5 ~+50 °C (No freezing)Rc3/81 MPaTAIYO DivisionRc1/81.5 MPaRc1/2Petroleum-based FluidAir-Oil converter0.2 MPa0.3xMain pressure+0.25MPa to 0.7MPaAC200V 50/60HzNormal Open Stop Valve1 sensor0.4 LN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40Flow control(Meter-out control)63 mm
H3FG00014781
Quote Required
TBD
-5 ~+50 °C (No freezing)Rc3/81 MPaTAIYO DivisionRc1/81.5 MPaRc1/2Petroleum-based FluidAir-Oil converter0.2 MPa0.3xMain pressure+0.25MPa to 0.7MPaAC200V 50/60HzNormal Open Stop Valve2 sensors0.4 LN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40Flow control(Meter-out control)63 mm
H3FG00014782
Quote Required
TBD
-5 ~+50 °C (No freezing)Rc3/81 MPaTAIYO DivisionRc1/81.5 MPaRc1/2Petroleum-based FluidAir-Oil converter0.2 MPa0.3xMain pressure+0.25MPa to 0.7MPaAC200V 50/60HzNormal Open Stop Valve3 sensors0.4 LN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40Flow control(Meter-out control)63 mm
H3FG00014783
Quote Required
TBD
-5 ~+50 °C (No freezing)Rc3/81 MPaTAIYO DivisionRc1/81.5 MPaRc1/2Petroleum-based FluidAir-Oil converter0.2 MPa0.3xMain pressure+0.25MPa to 0.7MPaAC200V 50/60HzNormal Open Stop Valve4 sensors0.4 LN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40Flow control(Meter-out control)63 mm
H3FG00014784
Quote Required
TBD
-5 ~+50 °C (No freezing)Rc3/81 MPaTAIYO DivisionRc1/81.5 MPaRc1/2Petroleum-based FluidAir-Oil converter0.2 MPa0.3xMain pressure+0.25MPa to 0.7MPaDC24VNormal Open Stop Valveno sensor0.4 LN/Ano sensor40Flow control(Meter-out control)63 mm
H3FG00014785
Quote Required
TBD
-5 ~+50 °C (No freezing)Rc3/81 MPaTAIYO DivisionRc1/81.5 MPaRc1/2Petroleum-based FluidAir-Oil converter0.2 MPa0.3xMain pressure+0.25MPa to 0.7MPaDC24VNormal Open Stop Valve1 sensor0.4 LN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40Flow control(Meter-out control)63 mm
H3FG00014786
Quote Required
TBD
-5 ~+50 °C (No freezing)Rc3/81 MPaTAIYO DivisionRc1/81.5 MPaRc1/2Petroleum-based FluidAir-Oil converter0.2 MPa0.3xMain pressure+0.25MPa to 0.7MPaDC24VNormal Open Stop Valve2 sensors0.4 LN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40Flow control(Meter-out control)63 mm
H3FG00014787
Quote Required
TBD
-5 ~+50 °C (No freezing)Rc3/81 MPaTAIYO DivisionRc1/81.5 MPaRc1/2Petroleum-based FluidAir-Oil converter0.2 MPa0.3xMain pressure+0.25MPa to 0.7MPaDC24VNormal Open Stop Valve3 sensors0.4 LN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40Flow control(Meter-out control)63 mm
H3FG00014788
Quote Required
TBD
-5 ~+50 °C (No freezing)Rc3/81 MPaTAIYO DivisionRc1/81.5 MPaRc1/2Petroleum-based FluidAir-Oil converter0.2 MPa0.3xMain pressure+0.25MPa to 0.7MPaDC24VNormal Open Stop Valve4 sensors0.4 LN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40Flow control(Meter-out control)63 mm
H3FG00014789
Quote Required
TBD
-5 ~+50 °C (No freezing)Rc3/81 MPaTAIYO DivisionRc1/81.5 MPaRc1/2Petroleum-based FluidAir-Oil converter0.2 MPa0.3xMain pressure+0.25MPa to 0.7MPaAC100V 50/60HzNormal Open Stop Valveno sensor0.4 LN/Ano sensor40Flow control(Meter-in control)63 mm
H3FG00014790
Quote Required
TBD
-5 ~+50 °C (No freezing)Rc3/81 MPaTAIYO DivisionRc1/81.5 MPaRc1/2Petroleum-based FluidAir-Oil converter0.2 MPa0.3xMain pressure+0.25MPa to 0.7MPaAC100V 50/60HzNormal Open Stop Valve1 sensor0.4 LN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40Flow control(Meter-in control)63 mm
H3FG00014791
Quote Required
TBD
-5 ~+50 °C (No freezing)Rc3/81 MPaTAIYO DivisionRc1/81.5 MPaRc1/2Petroleum-based FluidAir-Oil converter0.2 MPa0.3xMain pressure+0.25MPa to 0.7MPaAC100V 50/60HzNormal Open Stop Valve2 sensors0.4 LN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40Flow control(Meter-in control)63 mm
H3FG00014792
Quote Required
TBD
-5 ~+50 °C (No freezing)Rc3/81 MPaTAIYO DivisionRc1/81.5 MPaRc1/2Petroleum-based FluidAir-Oil converter0.2 MPa0.3xMain pressure+0.25MPa to 0.7MPaAC100V 50/60HzNormal Open Stop Valve3 sensors0.4 LN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40Flow control(Meter-in control)63 mm
H3FG00014793
Quote Required
TBD
-5 ~+50 °C (No freezing)Rc3/81 MPaTAIYO DivisionRc1/81.5 MPaRc1/2Petroleum-based FluidAir-Oil converter0.2 MPa0.3xMain pressure+0.25MPa to 0.7MPaAC100V 50/60HzNormal Open Stop Valve4 sensors0.4 LN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40Flow control(Meter-in control)63 mm
H3FG00014794
Quote Required
TBD
-5 ~+50 °C (No freezing)Rc3/81 MPaTAIYO DivisionRc1/81.5 MPaRc1/2Petroleum-based FluidAir-Oil converter0.2 MPa0.3xMain pressure+0.25MPa to 0.7MPaAC200V 50/60HzNormal Open Stop Valveno sensor0.4 LN/Ano sensor40Flow control(Meter-in control)63 mm
H3FG00014795
Quote Required
TBD
-5 ~+50 °C (No freezing)Rc3/81 MPaTAIYO DivisionRc1/81.5 MPaRc1/2Petroleum-based FluidAir-Oil converter0.2 MPa0.3xMain pressure+0.25MPa to 0.7MPaAC200V 50/60HzNormal Open Stop Valve1 sensor0.4 LN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40Flow control(Meter-in control)63 mm
H3FG00014796
Quote Required
TBD
-5 ~+50 °C (No freezing)Rc3/81 MPaTAIYO DivisionRc1/81.5 MPaRc1/2Petroleum-based FluidAir-Oil converter0.2 MPa0.3xMain pressure+0.25MPa to 0.7MPaAC200V 50/60HzNormal Open Stop Valve2 sensors0.4 LN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40Flow control(Meter-in control)63 mm
H3FG00014797
Quote Required
TBD
-5 ~+50 °C (No freezing)Rc3/81 MPaTAIYO DivisionRc1/81.5 MPaRc1/2Petroleum-based FluidAir-Oil converter0.2 MPa0.3xMain pressure+0.25MPa to 0.7MPaAC200V 50/60HzNormal Open Stop Valve3 sensors0.4 LN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40Flow control(Meter-in control)63 mm
H3FG00014798
Quote Required
TBD
-5 ~+50 °C (No freezing)Rc3/81 MPaTAIYO DivisionRc1/81.5 MPaRc1/2Petroleum-based FluidAir-Oil converter0.2 MPa0.3xMain pressure+0.25MPa to 0.7MPaAC200V 50/60HzNormal Open Stop Valve4 sensors0.4 LN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40Flow control(Meter-in control)63 mm