Air-Oil Unit Model:AHU2-063 (Convertor Capacity 0.16~1.6L)

Picture for category Air-Oil Unit Model:AHU2-063 (Convertor Capacity 0.16~1.6L)

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The AHU2 series is an Air-Oil Unit that converts pneumatic pressure into hydraulic control for constant speed control and arbitrary stop. Combinations such as those with flow control valves, those with throttle valves, and converters only are possible. It exerts more power when used in combination with our low-pressure hydraulic cylinder.


Markets:

・General Industry

・Machine Tools


Applications:

・General Industry

・Factory Automation

・Machine Tools


Features/Benefits:

・Because of hydraulic control, speed control is easy.

・With flow control, throttle, skip and stop valve, etc., select according to the application.

・The converter capacity is 0.16 to 20L.

・Some types are available with a switch.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceProduct StyleMinimum Opening PressureProof PressureLiquid Inlet Port SizeSupply Air Inlet Port SizePilot Port SizeFor Fluid TypePilot Pressure RatioMaximum Operating PressureDivisionOperating TemperatureDiameterAssembled Combined Valve TypeOptional AccessoriesSensor ConnectionCapacityMaximum Flow Rate (lpm)Assembled Control Valve TypeSensor typeInput Voltage
H3FG00014239
Quote Required
TBD
Air-Oil converter0.2 MPa1.5 MPaRc1/2Rc3/8Rc1/8Petroleum-based Fluid0.3xMain pressure+0.25MPa to 0.7MPa1 MPaTAIYO Division-5 ~+50 °C (No freezing)63 mmNomal Close Skip ValveN/Ano sensor0.25 L40Flow control(Meter-in control)no sensorDC24V
H3FG00014240
Quote Required
TBD
Air-Oil converter0.2 MPa1.5 MPaRc1/2Rc3/8Rc1/8Petroleum-based Fluid0.3xMain pressure+0.25MPa to 0.7MPa1 MPaTAIYO Division-5 ~+50 °C (No freezing)63 mmNomal Close Skip ValveN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)0.25 L40Flow control(Meter-in control)1 sensorDC24V
H3FG00014241
Quote Required
TBD
Air-Oil converter0.2 MPa1.5 MPaRc1/2Rc3/8Rc1/8Petroleum-based Fluid0.3xMain pressure+0.25MPa to 0.7MPa1 MPaTAIYO Division-5 ~+50 °C (No freezing)63 mmNomal Close Skip ValveN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)0.25 L40Flow control(Meter-in control)2 sensorsDC24V
H3FG00014242
Quote Required
TBD
Air-Oil converter0.2 MPa1.5 MPaRc1/2Rc3/8Rc1/8Petroleum-based Fluid0.3xMain pressure+0.25MPa to 0.7MPa1 MPaTAIYO Division-5 ~+50 °C (No freezing)63 mmNomal Close Skip ValveN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)0.25 L40Flow control(Meter-in control)3 sensorsDC24V
H3FG00014243
Quote Required
TBD
Air-Oil converter0.2 MPa1.5 MPaRc1/2Rc3/8Rc1/8Petroleum-based Fluid0.3xMain pressure+0.25MPa to 0.7MPa1 MPaTAIYO Division-5 ~+50 °C (No freezing)63 mmNomal Close Skip ValveN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)0.25 L40Flow control(Meter-in control)4 sensorsDC24V
H3FG00014244
Quote Required
TBD
Air-Oil converter0.2 MPa1.5 MPaRc1/2Rc3/8Rc1/8Petroleum-based Fluid0.3xMain pressure+0.25MPa to 0.7MPa1 MPaTAIYO Division-5 ~+50 °C (No freezing)63 mmNormal Open Skip ValveN/Ano sensor0.25 L40Flow control(Meter-out control)no sensorAC100V 50/60Hz
H3FG00014245
Quote Required
TBD
Air-Oil converter0.2 MPa1.5 MPaRc1/2Rc3/8Rc1/8Petroleum-based Fluid0.3xMain pressure+0.25MPa to 0.7MPa1 MPaTAIYO Division-5 ~+50 °C (No freezing)63 mmNormal Open Skip ValveN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)0.25 L40Flow control(Meter-out control)1 sensorAC100V 50/60Hz
H3FG00014246
Quote Required
TBD
Air-Oil converter0.2 MPa1.5 MPaRc1/2Rc3/8Rc1/8Petroleum-based Fluid0.3xMain pressure+0.25MPa to 0.7MPa1 MPaTAIYO Division-5 ~+50 °C (No freezing)63 mmNormal Open Skip ValveN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)0.25 L40Flow control(Meter-out control)2 sensorsAC100V 50/60Hz
H3FG00014247
Quote Required
TBD
Air-Oil converter0.2 MPa1.5 MPaRc1/2Rc3/8Rc1/8Petroleum-based Fluid0.3xMain pressure+0.25MPa to 0.7MPa1 MPaTAIYO Division-5 ~+50 °C (No freezing)63 mmNormal Open Skip ValveN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)0.25 L40Flow control(Meter-out control)3 sensorsAC100V 50/60Hz
H3FG00014248
Quote Required
TBD
Air-Oil converter0.2 MPa1.5 MPaRc1/2Rc3/8Rc1/8Petroleum-based Fluid0.3xMain pressure+0.25MPa to 0.7MPa1 MPaTAIYO Division-5 ~+50 °C (No freezing)63 mmNormal Open Skip ValveN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)0.25 L40Flow control(Meter-out control)4 sensorsAC100V 50/60Hz
H3FG00014249
Quote Required
TBD
Air-Oil converter0.2 MPa1.5 MPaRc1/2Rc3/8Rc1/8Petroleum-based Fluid0.3xMain pressure+0.25MPa to 0.7MPa1 MPaTAIYO Division-5 ~+50 °C (No freezing)63 mmNormal Open Skip ValveN/Ano sensor0.25 L40Flow control(Meter-out control)no sensorAC200V 50/60Hz
H3FG00014250
Quote Required
TBD
Air-Oil converter0.2 MPa1.5 MPaRc1/2Rc3/8Rc1/8Petroleum-based Fluid0.3xMain pressure+0.25MPa to 0.7MPa1 MPaTAIYO Division-5 ~+50 °C (No freezing)63 mmNormal Open Skip ValveN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)0.25 L40Flow control(Meter-out control)1 sensorAC200V 50/60Hz
H3FG00014251
Quote Required
TBD
Air-Oil converter0.2 MPa1.5 MPaRc1/2Rc3/8Rc1/8Petroleum-based Fluid0.3xMain pressure+0.25MPa to 0.7MPa1 MPaTAIYO Division-5 ~+50 °C (No freezing)63 mmNormal Open Skip ValveN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)0.25 L40Flow control(Meter-out control)2 sensorsAC200V 50/60Hz
H3FG00014252
Quote Required
TBD
Air-Oil converter0.2 MPa1.5 MPaRc1/2Rc3/8Rc1/8Petroleum-based Fluid0.3xMain pressure+0.25MPa to 0.7MPa1 MPaTAIYO Division-5 ~+50 °C (No freezing)63 mmNormal Open Skip ValveN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)0.25 L40Flow control(Meter-out control)3 sensorsAC200V 50/60Hz
H3FG00014253
Quote Required
TBD
Air-Oil converter0.2 MPa1.5 MPaRc1/2Rc3/8Rc1/8Petroleum-based Fluid0.3xMain pressure+0.25MPa to 0.7MPa1 MPaTAIYO Division-5 ~+50 °C (No freezing)63 mmNormal Open Skip ValveN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)0.25 L40Flow control(Meter-out control)4 sensorsAC200V 50/60Hz
H3FG00014254
Quote Required
TBD
Air-Oil converter0.2 MPa1.5 MPaRc1/2Rc3/8Rc1/8Petroleum-based Fluid0.3xMain pressure+0.25MPa to 0.7MPa1 MPaTAIYO Division-5 ~+50 °C (No freezing)63 mmNormal Open Skip ValveN/Ano sensor0.25 L40Flow control(Meter-out control)no sensorDC24V
H3FG00014255
Quote Required
TBD
Air-Oil converter0.2 MPa1.5 MPaRc1/2Rc3/8Rc1/8Petroleum-based Fluid0.3xMain pressure+0.25MPa to 0.7MPa1 MPaTAIYO Division-5 ~+50 °C (No freezing)63 mmNormal Open Skip ValveN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)0.25 L40Flow control(Meter-out control)1 sensorDC24V
H3FG00014256
Quote Required
TBD
Air-Oil converter0.2 MPa1.5 MPaRc1/2Rc3/8Rc1/8Petroleum-based Fluid0.3xMain pressure+0.25MPa to 0.7MPa1 MPaTAIYO Division-5 ~+50 °C (No freezing)63 mmNormal Open Skip ValveN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)0.25 L40Flow control(Meter-out control)2 sensorsDC24V
H3FG00014257
Quote Required
TBD
Air-Oil converter0.2 MPa1.5 MPaRc1/2Rc3/8Rc1/8Petroleum-based Fluid0.3xMain pressure+0.25MPa to 0.7MPa1 MPaTAIYO Division-5 ~+50 °C (No freezing)63 mmNormal Open Skip ValveN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)0.25 L40Flow control(Meter-out control)3 sensorsDC24V
H3FG00014258
Quote Required
TBD
Air-Oil converter0.2 MPa1.5 MPaRc1/2Rc3/8Rc1/8Petroleum-based Fluid0.3xMain pressure+0.25MPa to 0.7MPa1 MPaTAIYO Division-5 ~+50 °C (No freezing)63 mmNormal Open Skip ValveN/AZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)0.25 L40Flow control(Meter-out control)4 sensorsDC24V