Air-Oil Unit Model:AHU2-063 (Convertor Capacity 0.16~1.6L)

Picture for category Air-Oil Unit Model:AHU2-063 (Convertor Capacity 0.16~1.6L)

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The AHU2 series is an Air-Oil Unit that converts pneumatic pressure into hydraulic control for constant speed control and arbitrary stop. Combinations such as those with flow control valves, those with throttle valves, and converters only are possible. It exerts more power when used in combination with our low-pressure hydraulic cylinder.


Markets:

・General Industry

・Machine Tools


Applications:

・General Industry

・Factory Automation

・Machine Tools


Features/Benefits:

・Because of hydraulic control, speed control is easy.

・With flow control, throttle, skip and stop valve, etc., select according to the application.

・The converter capacity is 0.16 to 20L.

・Some types are available with a switch.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceFor Fluid TypeSupply Air Inlet Port SizeProof PressureLiquid Inlet Port SizeDivisionOperating TemperatureMinimum Opening PressurePilot Port SizeProduct StyleMaximum Operating PressurePilot Pressure RatioSensor typeCapacityInput VoltageDiameterAssembled Combined Valve TypeSensor ConnectionMaximum Flow Rate (lpm)Optional AccessoriesAssembled Control Valve Type
H3FG00016379
Quote Required
TBD
Petroleum-based FluidRc3/81.5 MPaRc1/2TAIYO Division-5 ~+50 °C (No freezing)0.05 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPano sensor1.6 LAC200V 50/60Hz63 mmNomal Close Stop Valveno sensor40N/AThrottle control(Meter-in control)
H3FG00016380
Quote Required
TBD
Petroleum-based FluidRc3/81.5 MPaRc1/2TAIYO Division-5 ~+50 °C (No freezing)0.05 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPa1 sensor1.6 LAC200V 50/60Hz63 mmNomal Close Stop ValveZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40N/AThrottle control(Meter-in control)
H3FG00016381
Quote Required
TBD
Petroleum-based FluidRc3/81.5 MPaRc1/2TAIYO Division-5 ~+50 °C (No freezing)0.05 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPa2 sensors1.6 LAC200V 50/60Hz63 mmNomal Close Stop ValveZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40N/AThrottle control(Meter-in control)
H3FG00016382
Quote Required
TBD
Petroleum-based FluidRc3/81.5 MPaRc1/2TAIYO Division-5 ~+50 °C (No freezing)0.05 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPa3 sensors1.6 LAC200V 50/60Hz63 mmNomal Close Stop ValveZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40N/AThrottle control(Meter-in control)
H3FG00016383
Quote Required
TBD
Petroleum-based FluidRc3/81.5 MPaRc1/2TAIYO Division-5 ~+50 °C (No freezing)0.05 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPa4 sensors1.6 LAC200V 50/60Hz63 mmNomal Close Stop ValveZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40N/AThrottle control(Meter-in control)
H3FG00016384
Quote Required
TBD
Petroleum-based FluidRc3/81.5 MPaRc1/2TAIYO Division-5 ~+50 °C (No freezing)0.05 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPano sensor1.6 LDC24V63 mmNomal Close Stop Valveno sensor40N/AThrottle control(Meter-in control)
H3FG00016385
Quote Required
TBD
Petroleum-based FluidRc3/81.5 MPaRc1/2TAIYO Division-5 ~+50 °C (No freezing)0.05 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPa1 sensor1.6 LDC24V63 mmNomal Close Stop ValveZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40N/AThrottle control(Meter-in control)
H3FG00016386
Quote Required
TBD
Petroleum-based FluidRc3/81.5 MPaRc1/2TAIYO Division-5 ~+50 °C (No freezing)0.05 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPa2 sensors1.6 LDC24V63 mmNomal Close Stop ValveZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40N/AThrottle control(Meter-in control)
H3FG00016387
Quote Required
TBD
Petroleum-based FluidRc3/81.5 MPaRc1/2TAIYO Division-5 ~+50 °C (No freezing)0.05 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPa3 sensors1.6 LDC24V63 mmNomal Close Stop ValveZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40N/AThrottle control(Meter-in control)
H3FG00016388
Quote Required
TBD
Petroleum-based FluidRc3/81.5 MPaRc1/2TAIYO Division-5 ~+50 °C (No freezing)0.05 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPa4 sensors1.6 LDC24V63 mmNomal Close Stop ValveZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40N/AThrottle control(Meter-in control)
H3FG00016389
Quote Required
TBD
Petroleum-based FluidRc3/81.5 MPaRc1/2TAIYO Division-5 ~+50 °C (No freezing)0.05 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPano sensor1.6 LAC100V 50/60Hz63 mmNormal Open Stop Valveno sensor40N/AThrottle control(Meter-out control)
H3FG00016390
Quote Required
TBD
Petroleum-based FluidRc3/81.5 MPaRc1/2TAIYO Division-5 ~+50 °C (No freezing)0.05 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPa1 sensor1.6 LAC100V 50/60Hz63 mmNormal Open Stop ValveZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40N/AThrottle control(Meter-out control)
H3FG00016391
Quote Required
TBD
Petroleum-based FluidRc3/81.5 MPaRc1/2TAIYO Division-5 ~+50 °C (No freezing)0.05 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPa2 sensors1.6 LAC100V 50/60Hz63 mmNormal Open Stop ValveZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40N/AThrottle control(Meter-out control)
H3FG00016392
Quote Required
TBD
Petroleum-based FluidRc3/81.5 MPaRc1/2TAIYO Division-5 ~+50 °C (No freezing)0.05 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPa3 sensors1.6 LAC100V 50/60Hz63 mmNormal Open Stop ValveZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40N/AThrottle control(Meter-out control)
H3FG00016393
Quote Required
TBD
Petroleum-based FluidRc3/81.5 MPaRc1/2TAIYO Division-5 ~+50 °C (No freezing)0.05 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPa4 sensors1.6 LAC100V 50/60Hz63 mmNormal Open Stop ValveZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40N/AThrottle control(Meter-out control)
H3FG00016394
Quote Required
TBD
Petroleum-based FluidRc3/81.5 MPaRc1/2TAIYO Division-5 ~+50 °C (No freezing)0.05 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPano sensor1.6 LAC200V 50/60Hz63 mmNormal Open Stop Valveno sensor40N/AThrottle control(Meter-out control)
H3FG00016395
Quote Required
TBD
Petroleum-based FluidRc3/81.5 MPaRc1/2TAIYO Division-5 ~+50 °C (No freezing)0.05 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPa1 sensor1.6 LAC200V 50/60Hz63 mmNormal Open Stop ValveZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40N/AThrottle control(Meter-out control)
H3FG00016396
Quote Required
TBD
Petroleum-based FluidRc3/81.5 MPaRc1/2TAIYO Division-5 ~+50 °C (No freezing)0.05 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPa2 sensors1.6 LAC200V 50/60Hz63 mmNormal Open Stop ValveZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40N/AThrottle control(Meter-out control)
H3FG00016397
Quote Required
TBD
Petroleum-based FluidRc3/81.5 MPaRc1/2TAIYO Division-5 ~+50 °C (No freezing)0.05 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPa3 sensors1.6 LAC200V 50/60Hz63 mmNormal Open Stop ValveZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40N/AThrottle control(Meter-out control)
H3FG00016398
Quote Required
TBD
Petroleum-based FluidRc3/81.5 MPaRc1/2TAIYO Division-5 ~+50 °C (No freezing)0.05 MPaRc1/8Air-Oil converter1 MPa0.3xMain pressure+0.25MPa to 0.7MPa4 sensors1.6 LAC200V 50/60Hz63 mmNormal Open Stop ValveZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)40N/AThrottle control(Meter-out control)