Air Oil Cooler with Hydraulic Motor - ULHC Series - (Americas)
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker's ULHC Air Oil Cooler offers quiet fan operation, low pressure drop and high cooling capability. These coolers utilizes a robust bar and plate construction, providing a more efficient and compact design when compared to traditional tube and fin construction. The ULHC Series features 6 different hydraulic motor displacements to meet application requirements.
Markets:
• Construction
• Forestry
• Material Handling
• Agriculture
• Industrial
• Marine & Offshore
• Oil & Gas
• Renewable & Wind Energy
• Power Generation
Features/Benefits:
• Up to 215hp of cooling capacity (70°F ETD)
• Compact design results in lighter weight, higher cooling capacity, and lower pressure drop
• Optimized design results in reliable and long lasting cooling with low service and maintenance costs
• Quiet fan design due to optimization of blade and materials
• Extra corrosion protection available for use in marine/offshore and extreme applications
• Several options available: Thermal switch, Pressure bypass, Air filter, Fan guard/screen, etc.
Applications:
• Aerial Lift Equipment
• Agriculture Machinery
• Construction Equipment
• Forestry Equipment
• Material Handling Equipment
• Turf Equipment
• Vocational Equipment and Special Use Work Vehicles
• Hydraulic power units
• Lubrication systems
• Hydraulic presses
• Plastics machinery
Read More...Markets:
• Construction
• Forestry
• Material Handling
• Agriculture
• Industrial
• Marine & Offshore
• Oil & Gas
• Renewable & Wind Energy
• Power Generation
Features/Benefits:
• Up to 215hp of cooling capacity (70°F ETD)
• Compact design results in lighter weight, higher cooling capacity, and lower pressure drop
• Optimized design results in reliable and long lasting cooling with low service and maintenance costs
• Quiet fan design due to optimization of blade and materials
• Extra corrosion protection available for use in marine/offshore and extreme applications
• Several options available: Thermal switch, Pressure bypass, Air filter, Fan guard/screen, etc.
Applications:
• Aerial Lift Equipment
• Agriculture Machinery
• Construction Equipment
• Forestry Equipment
• Material Handling Equipment
• Turf Equipment
• Vocational Equipment and Special Use Work Vehicles
• Hydraulic power units
• Lubrication systems
• Hydraulic presses
• Plastics machinery
| Action | Part No. | Availability | Partner Available | Price | Connection Thread Size | Weight | Length | Maximum Fluid Temperature | For Fluid Type | Maximum Operating Speed | Width | Maximum Operating Pressure | Materials of Construction | Noise Level | Maximum Cooling Capacity | Flow Rate | Division | Port Size | Height | Switch Type | Size | Bypass Options | Motor Displacement (cc/rev) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ULHC-058-F-160SW | Quote Required | TBD | 1-7/8"-12 | 170 | 34.2 | 250 | Mineral Oil | 1850 RPM (Fan) | 20.1 | 300 | Aluminum (Cooler Core) | 75 dBA @ 750 rpm | 71.5 HP @ 750 rpm | 105.6 | Accumulator and Cooler Division | 1-1/2 inch (#24) | 35.4 | 160° F thermal switch | Size 058 | no bypass | 25.2 cm3/rev | ||
| ULHC-058-F-175SA | Quote Required | TBD | 1-7/8"-12 | 170 | 34.2 | 250 | Mineral Oil | 1850 RPM (Fan) | 20.1 | 300 | Aluminum (Cooler Core) | 75 dBA @ 750 rpm | 71.5 HP @ 750 rpm | 105.6 | Accumulator and Cooler Division | 1-1/2 inch (#24) | 35.4 | 175° F thermal switch | Size 058 | 20 psi External Hose Bypass | 25.2 cm3/rev | ||
| ULHC-058-F-175SB | Quote Required | TBD | 1-7/8"-12 | 170 | 34.2 | 250 | Water Glycol | 1850 RPM (Fan) | 20.1 | 300 | Aluminum (Cooler Core) | 75 dBA @ 750 rpm | 71.5 HP @ 750 rpm | 105.6 | Accumulator and Cooler Division | 1-1/2 inch (#24) | 35.4 | 175° F thermal switch | Size 058 | 65 psi External Hose Bypass | 25.2 cm3/rev | ||
| ULHC-058-F-175SW | Quote Required | TBD | 1-7/8"-12 | 170 | 34.2 | 250 | Mineral Oil | 1850 RPM (Fan) | 20.1 | 300 | Aluminum (Cooler Core) | 75 dBA @ 750 rpm | 71.5 HP @ 750 rpm | 105.6 | Accumulator and Cooler Division | 1-1/2 inch (#24) | 35.4 | 175° F thermal switch | Size 058 | no bypass | 25.2 cm3/rev | ||
| ULHC-058-W-000SA | Quote Required | TBD | 1-7/8"-12 | 170 | 34.2 | 250 | Mineral Oil | 1850 RPM (Fan) | 20.1 | 300 | Aluminum (Cooler Core) | 75 dBA @ 750 rpm | 71.5 HP @ 750 rpm | 105.6 | Accumulator and Cooler Division | 1-1/2 inch (#24) | 35.4 | No Thermal Switch | Size 058 | 20 psi External Hose Bypass | No hydraulic motor | ||
| ULHC-058-W-000SB | Quote Required | TBD | 1-7/8"-12 | 170 | 34.2 | 250 | Mineral Oil | 1850 RPM (Fan) | 20.1 | 300 | Aluminum (Cooler Core) | 75 dBA @ 750 rpm | 71.5 HP @ 750 rpm | 105.6 | Accumulator and Cooler Division | 1-1/2 inch (#24) | 35.4 | No Thermal Switch | Size 058 | 65 psi External Hose Bypass | No hydraulic motor | ||
| ULHC-058-W-000SW | Quote Required | TBD | 1-7/8"-12 | 170 | 34.2 | 250 | Mineral Oil | 1850 RPM (Fan) | 20.1 | 300 | Aluminum (Cooler Core) | 75 dBA @ 750 rpm | 71.5 HP @ 750 rpm | 105.6 | Accumulator and Cooler Division | 1-1/2 inch (#24) | 35.4 | No Thermal Switch | Size 058 | no bypass | No hydraulic motor | ||
| ULHC-058-W-100SA | Quote Required | TBD | 1-7/8"-12 | 170 | 34.2 | 250 | Mineral Oil | 1850 RPM (Fan) | 20.1 | 300 | Aluminum (Cooler Core) | 75 dBA @ 750 rpm | 71.5 HP @ 750 rpm | 105.6 | Accumulator and Cooler Division | 1-1/2 inch (#24) | 35.4 | 100° F thermal switch | Size 058 | 20 psi External Hose Bypass | No hydraulic motor | ||
| ULHC-058-W-100SB | Quote Required | TBD | 1-7/8"-12 | 170 | 34.2 | 250 | Mineral Oil | 1850 RPM (Fan) | 20.1 | 300 | Aluminum (Cooler Core) | 75 dBA @ 750 rpm | 71.5 HP @ 750 rpm | 105.6 | Accumulator and Cooler Division | 1-1/2 inch (#24) | 35.4 | 100° F thermal switch | Size 058 | 65 psi External Hose Bypass | No hydraulic motor | ||
| ULHC-058-W-100SW | Quote Required | TBD | 1-7/8"-12 | 170 | 34.2 | 250 | Mineral Oil | 1850 RPM (Fan) | 20.1 | 300 | Aluminum (Cooler Core) | 75 dBA @ 750 rpm | 71.5 HP @ 750 rpm | 105.6 | Accumulator and Cooler Division | 1-1/2 inch (#24) | 35.4 | 100° F thermal switch | Size 058 | no bypass | No hydraulic motor | ||
| ULHC-058-W-120SA | Quote Required | TBD | 1-7/8"-12 | 170 | 34.2 | 250 | Mineral Oil | 1850 RPM (Fan) | 20.1 | 300 | Aluminum (Cooler Core) | 75 dBA @ 750 rpm | 71.5 HP @ 750 rpm | 105.6 | Accumulator and Cooler Division | 1-1/2 inch (#24) | 35.4 | 120° F thermal switch | Size 058 | 20 psi External Hose Bypass | No hydraulic motor | ||
| ULHC-058-W-120SB | Quote Required | TBD | 1-7/8"-12 | 170 | 34.2 | 250 | Mineral Oil | 1850 RPM (Fan) | 20.1 | 300 | Aluminum (Cooler Core) | 75 dBA @ 750 rpm | 71.5 HP @ 750 rpm | 105.6 | Accumulator and Cooler Division | 1-1/2 inch (#24) | 35.4 | 120° F thermal switch | Size 058 | 65 psi External Hose Bypass | No hydraulic motor | ||
| ULHC-058-W-120SW | Quote Required | TBD | 1-7/8"-12 | 170 | 34.2 | 250 | Mineral Oil | 1850 RPM (Fan) | 20.1 | 300 | Aluminum (Cooler Core) | 75 dBA @ 750 rpm | 71.5 HP @ 750 rpm | 105.6 | Accumulator and Cooler Division | 1-1/2 inch (#24) | 35.4 | 120° F thermal switch | Size 058 | no bypass | No hydraulic motor | ||
| ULHC-058-W-140SA | Quote Required | TBD | 1-7/8"-12 | 170 | 34.2 | 250 | Mineral Oil | 1850 RPM (Fan) | 20.1 | 300 | Aluminum (Cooler Core) | 75 dBA @ 750 rpm | 71.5 HP @ 750 rpm | 105.6 | Accumulator and Cooler Division | 1-1/2 inch (#24) | 35.4 | 140° F thermal switch | Size 058 | 20 psi External Hose Bypass | No hydraulic motor | ||
| ULHC-058-W-140SB | Quote Required | TBD | 1-7/8"-12 | 170 | 34.2 | 250 | Mineral Oil | 1850 RPM (Fan) | 20.1 | 300 | Aluminum (Cooler Core) | 75 dBA @ 750 rpm | 71.5 HP @ 750 rpm | 105.6 | Accumulator and Cooler Division | 1-1/2 inch (#24) | 35.4 | 140° F thermal switch | Size 058 | 65 psi External Hose Bypass | No hydraulic motor | ||
| ULHC-058-W-140SW | Quote Required | TBD | 1-7/8"-12 | 170 | 34.2 | 250 | Mineral Oil | 1850 RPM (Fan) | 20.1 | 300 | Aluminum (Cooler Core) | 75 dBA @ 750 rpm | 71.5 HP @ 750 rpm | 105.6 | Accumulator and Cooler Division | 1-1/2 inch (#24) | 35.4 | 140° F thermal switch | Size 058 | no bypass | No hydraulic motor | ||
| ULHC-058-W-160SA | Quote Required | TBD | 1-7/8"-12 | 170 | 34.2 | 250 | Mineral Oil | 1850 RPM (Fan) | 20.1 | 300 | Aluminum (Cooler Core) | 75 dBA @ 750 rpm | 71.5 HP @ 750 rpm | 105.6 | Accumulator and Cooler Division | 1-1/2 inch (#24) | 35.4 | 160° F thermal switch | Size 058 | 20 psi External Hose Bypass | No hydraulic motor | ||
| ULHC-058-W-160SB | Quote Required | TBD | 1-7/8"-12 | 170 | 34.2 | 250 | Mineral Oil | 1850 RPM (Fan) | 20.1 | 300 | Aluminum (Cooler Core) | 75 dBA @ 750 rpm | 71.5 HP @ 750 rpm | 105.6 | Accumulator and Cooler Division | 1-1/2 inch (#24) | 35.4 | 160° F thermal switch | Size 058 | 65 psi External Hose Bypass | No hydraulic motor | ||
| ULHC-058-W-160SW | Quote Required | TBD | 1-7/8"-12 | 170 | 34.2 | 250 | Mineral Oil | 1850 RPM (Fan) | 20.1 | 300 | Aluminum (Cooler Core) | 75 dBA @ 750 rpm | 71.5 HP @ 750 rpm | 105.6 | Accumulator and Cooler Division | 1-1/2 inch (#24) | 35.4 | 160° F thermal switch | Size 058 | no bypass | No hydraulic motor | ||
| ULHC-058-W-175SA | Quote Required | TBD | 1-7/8"-12 | 170 | 34.2 | 250 | Mineral Oil | 1850 RPM (Fan) | 20.1 | 300 | Aluminum (Cooler Core) | 75 dBA @ 750 rpm | 71.5 HP @ 750 rpm | 105.6 | Accumulator and Cooler Division | 1-1/2 inch (#24) | 35.4 | 175° F thermal switch | Size 058 | 20 psi External Hose Bypass | No hydraulic motor |