- Availability & Price
- Search SKU
Filter by attributes
- Bypass Options
- Motor Displacement (cc/rev)
- Size
- Switch Type
Filter by manufacturer
Recently viewed products
-
Parker SNPT4-400-B-4MO-EMA - Wireless SensoNODE™Blue Sensors with Voice of the Machine™ Mobile App - Route-based Condition Monitoring -
Parker 12M1SC10-316 - Parker Tube Fitting, Male Connector to SAE Straight Thread - A-LOK Series -
Parker FDD15-02 - Compressed Air & Gas - Up to 300 PSIG - FDD Desiccant Dryer Series
Air Oil Cooler with Hydraulic Motor - ULHC Series - (Americas)
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker's ULHC Air Oil Cooler offers quiet fan operation, low pressure drop and high cooling capability. These coolers utilizes a robust bar and plate construction, providing a more efficient and compact design when compared to traditional tube and fin construction. The ULHC Series features 6 different hydraulic motor displacements to meet application requirements.
Markets:
• Construction
• Forestry
• Material Handling
• Agriculture
• Industrial
• Marine & Offshore
• Oil & Gas
• Renewable & Wind Energy
• Power Generation
Features/Benefits:
• Up to 215hp of cooling capacity (70°F ETD)
• Compact design results in lighter weight, higher cooling capacity, and lower pressure drop
• Optimized design results in reliable and long lasting cooling with low service and maintenance costs
• Quiet fan design due to optimization of blade and materials
• Extra corrosion protection available for use in marine/offshore and extreme applications
• Several options available: Thermal switch, Pressure bypass, Air filter, Fan guard/screen, etc.
Applications:
• Aerial Lift Equipment
• Agriculture Machinery
• Construction Equipment
• Forestry Equipment
• Material Handling Equipment
• Turf Equipment
• Vocational Equipment and Special Use Work Vehicles
• Hydraulic power units
• Lubrication systems
• Hydraulic presses
• Plastics machinery
Read More...Markets:
• Construction
• Forestry
• Material Handling
• Agriculture
• Industrial
• Marine & Offshore
• Oil & Gas
• Renewable & Wind Energy
• Power Generation
Features/Benefits:
• Up to 215hp of cooling capacity (70°F ETD)
• Compact design results in lighter weight, higher cooling capacity, and lower pressure drop
• Optimized design results in reliable and long lasting cooling with low service and maintenance costs
• Quiet fan design due to optimization of blade and materials
• Extra corrosion protection available for use in marine/offshore and extreme applications
• Several options available: Thermal switch, Pressure bypass, Air filter, Fan guard/screen, etc.
Applications:
• Aerial Lift Equipment
• Agriculture Machinery
• Construction Equipment
• Forestry Equipment
• Material Handling Equipment
• Turf Equipment
• Vocational Equipment and Special Use Work Vehicles
• Hydraulic power units
• Lubrication systems
• Hydraulic presses
• Plastics machinery
| Action | Part No. | Availability | Partner Available | Price | Maximum Operating Speed | Port Size | Maximum Fluid Temperature | Maximum Cooling Capacity | Flow Rate | Height | Connection Thread Size | Materials of Construction | Weight | Maximum Operating Pressure | Width | Noise Level | For Fluid Type | Length | Division | Switch Type | Bypass Options | Size | Motor Displacement (cc/rev) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ULHC-007-D-120SA | Quote Required | TBD | 3500 RPM (Fan) | 1 inch (#16) | 250 | 12 HP @ 1500 rpm | 33 | 15.6 | 1-5/16"-12 | Aluminum (Cooler Core) | 22 | 300 | 20.1 | 62 dBA @ 1500 rpm | Mineral Oil | 14.4 | Accumulator and Cooler Division | 120° F thermal switch | 20 psi External Hose Bypass | Size 007 | 16.8 cm3/rev | ||
| ULHC-007-D-120SB | Quote Required | TBD | 3500 RPM (Fan) | 1 inch (#16) | 250 | 12 HP @ 1500 rpm | 33 | 15.6 | 1-5/16"-12 | Aluminum (Cooler Core) | 22 | 300 | 20.1 | 62 dBA @ 1500 rpm | Mineral Oil | 14.4 | Accumulator and Cooler Division | 120° F thermal switch | 65 psi External Hose Bypass | Size 007 | 16.8 cm3/rev | ||
| ULHC-007-D-120SW | Quote Required | TBD | 3500 RPM (Fan) | 1 inch (#16) | 250 | 12 HP @ 1500 rpm | 33 | 15.6 | 1-5/16"-12 | Aluminum (Cooler Core) | 22 | 300 | 20.1 | 62 dBA @ 1500 rpm | Mineral Oil | 14.4 | Accumulator and Cooler Division | 120° F thermal switch | no bypass | Size 007 | 16.8 cm3/rev | ||
| ULHC-007-D-140SA | Quote Required | TBD | 3500 RPM (Fan) | 1 inch (#16) | 250 | 12 HP @ 1500 rpm | 33 | 15.6 | 1-5/16"-12 | Aluminum (Cooler Core) | 22 | 300 | 20.1 | 62 dBA @ 1500 rpm | Mineral Oil | 14.4 | Accumulator and Cooler Division | 140° F thermal switch | 20 psi External Hose Bypass | Size 007 | 16.8 cm3/rev | ||
| ULHC-007-D-140SB | Quote Required | TBD | 3500 RPM (Fan) | 1 inch (#16) | 250 | 12 HP @ 1500 rpm | 33 | 15.6 | 1-5/16"-12 | Aluminum (Cooler Core) | 22 | 300 | 20.1 | 62 dBA @ 1500 rpm | Mineral Oil | 14.4 | Accumulator and Cooler Division | 140° F thermal switch | 65 psi External Hose Bypass | Size 007 | 16.8 cm3/rev | ||
| ULHC-007-D-140SW | Quote Required | TBD | 3500 RPM (Fan) | 1 inch (#16) | 250 | 12 HP @ 1500 rpm | 33 | 15.6 | 1-5/16"-12 | Aluminum (Cooler Core) | 22 | 300 | 20.1 | 62 dBA @ 1500 rpm | Mineral Oil | 14.4 | Accumulator and Cooler Division | 140° F thermal switch | no bypass | Size 007 | 16.8 cm3/rev | ||
| ULHC-007-D-160SA | Quote Required | TBD | 3500 RPM (Fan) | 1 inch (#16) | 250 | 12 HP @ 1500 rpm | 33 | 15.6 | 1-5/16"-12 | Aluminum (Cooler Core) | 22 | 300 | 20.1 | 62 dBA @ 1500 rpm | Mineral Oil | 14.4 | Accumulator and Cooler Division | 160° F thermal switch | 20 psi External Hose Bypass | Size 007 | 16.8 cm3/rev | ||
| ULHC-007-D-160SB | Quote Required | TBD | 3500 RPM (Fan) | 1 inch (#16) | 250 | 12 HP @ 1500 rpm | 33 | 15.6 | 1-5/16"-12 | Aluminum (Cooler Core) | 22 | 300 | 20.1 | 62 dBA @ 1500 rpm | Mineral Oil | 14.4 | Accumulator and Cooler Division | 160° F thermal switch | 65 psi External Hose Bypass | Size 007 | 16.8 cm3/rev | ||
| ULHC-007-D-160SW | Quote Required | TBD | 3500 RPM (Fan) | 1 inch (#16) | 250 | 12 HP @ 1500 rpm | 33 | 15.6 | 1-5/16"-12 | Aluminum (Cooler Core) | 22 | 300 | 20.1 | 62 dBA @ 1500 rpm | Mineral Oil | 14.4 | Accumulator and Cooler Division | 160° F thermal switch | no bypass | Size 007 | 16.8 cm3/rev | ||
| ULHC-007-D-175SA | Quote Required | TBD | 3500 RPM (Fan) | 1 inch (#16) | 250 | 12 HP @ 1500 rpm | 33 | 15.6 | 1-5/16"-12 | Aluminum (Cooler Core) | 22 | 300 | 20.1 | 62 dBA @ 1500 rpm | Water Glycol | 14.4 | Accumulator and Cooler Division | 175° F thermal switch | 20 psi External Hose Bypass | Size 007 | 16.8 cm3/rev | ||
| ULHC-007-D-175SB | Quote Required | TBD | 3500 RPM (Fan) | 1 inch (#16) | 250 | 12 HP @ 1500 rpm | 33 | 15.6 | 1-5/16"-12 | Aluminum (Cooler Core) | 22 | 300 | 20.1 | 62 dBA @ 1500 rpm | Mineral Oil | 14.4 | Accumulator and Cooler Division | 175° F thermal switch | 65 psi External Hose Bypass | Size 007 | 16.8 cm3/rev | ||
| ULHC-007-D-175SW | Quote Required | TBD | 3500 RPM (Fan) | 1 inch (#16) | 250 | 12 HP @ 1500 rpm | 33 | 15.6 | 1-5/16"-12 | Aluminum (Cooler Core) | 22 | 300 | 20.1 | 62 dBA @ 1500 rpm | Mineral Oil | 14.4 | Accumulator and Cooler Division | 175° F thermal switch | no bypass | Size 007 | 16.8 cm3/rev | ||
| ULHC-007-E-000SA | Quote Required | TBD | 3500 RPM (Fan) | 1 inch (#16) | 250 | 12 HP @ 1500 rpm | 33 | 15.6 | 1-5/16"-12 | Aluminum (Cooler Core) | 22 | 300 | 20.1 | 62 dBA @ 1500 rpm | Mineral Oil | 14.4 | Accumulator and Cooler Division | No Thermal Switch | 20 psi External Hose Bypass | Size 007 | 19.2 cm3/rev | ||
| ULHC-007-E-000SB | Quote Required | TBD | 3500 RPM (Fan) | 1 inch (#16) | 250 | 12 HP @ 1500 rpm | 33 | 15.6 | 1-5/16"-12 | Aluminum (Cooler Core) | 22 | 300 | 20.1 | 62 dBA @ 1500 rpm | Mineral Oil | 14.4 | Accumulator and Cooler Division | No Thermal Switch | 65 psi External Hose Bypass | Size 007 | 19.2 cm3/rev | ||
| ULHC-007-E-000SW | Quote Required | TBD | 3500 RPM (Fan) | 1 inch (#16) | 250 | 12 HP @ 1500 rpm | 33 | 15.6 | 1-5/16"-12 | Aluminum (Cooler Core) | 22 | 300 | 20.1 | 62 dBA @ 1500 rpm | Mineral Oil | 14.4 | Accumulator and Cooler Division | No Thermal Switch | no bypass | Size 007 | 19.2 cm3/rev | ||
| ULHC-007-E-100SA | Quote Required | TBD | 3500 RPM (Fan) | 1 inch (#16) | 250 | 12 HP @ 1500 rpm | 33 | 15.6 | 1-5/16"-12 | Aluminum (Cooler Core) | 22 | 300 | 20.1 | 62 dBA @ 1500 rpm | Mineral Oil | 14.4 | Accumulator and Cooler Division | 100° F thermal switch | 20 psi External Hose Bypass | Size 007 | 19.2 cm3/rev | ||
| ULHC-007-E-100SB | Quote Required | TBD | 3500 RPM (Fan) | 1 inch (#16) | 250 | 12 HP @ 1500 rpm | 33 | 15.6 | 1-5/16"-12 | Aluminum (Cooler Core) | 22 | 300 | 20.1 | 62 dBA @ 1500 rpm | Mineral Oil | 14.4 | Accumulator and Cooler Division | 100° F thermal switch | 65 psi External Hose Bypass | Size 007 | 19.2 cm3/rev | ||
| ULHC-007-E-100SW | Quote Required | TBD | 3500 RPM (Fan) | 1 inch (#16) | 250 | 12 HP @ 1500 rpm | 33 | 15.6 | 1-5/16"-12 | Aluminum (Cooler Core) | 22 | 300 | 20.1 | 62 dBA @ 1500 rpm | Mineral Oil | 14.4 | Accumulator and Cooler Division | 100° F thermal switch | no bypass | Size 007 | 19.2 cm3/rev | ||
| ULHC-007-E-120SA | Quote Required | TBD | 3500 RPM (Fan) | 1 inch (#16) | 250 | 12 HP @ 1500 rpm | 33 | 15.6 | 1-5/16"-12 | Aluminum (Cooler Core) | 22 | 300 | 20.1 | 62 dBA @ 1500 rpm | Mineral Oil | 14.4 | Accumulator and Cooler Division | 120° F thermal switch | 20 psi External Hose Bypass | Size 007 | 19.2 cm3/rev | ||
| ULHC-007-E-120SB | Quote Required | TBD | 3500 RPM (Fan) | 1 inch (#16) | 250 | 12 HP @ 1500 rpm | 33 | 15.6 | 1-5/16"-12 | Aluminum (Cooler Core) | 22 | 300 | 20.1 | 62 dBA @ 1500 rpm | Mineral Oil | 14.4 | Accumulator and Cooler Division | 120° F thermal switch | 65 psi External Hose Bypass | Size 007 | 19.2 cm3/rev |