• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Body Material
  • Coil Type
  • Function
  • Ingress Protection Rating
  • Input Voltage
  • Installation
  • Insulation Class
  • Main Flow Coefficient
  • Maximum Ambient Temperature
More Filters...
Filter by manufacturer
Manufacturers

7 Family - 4 Way (5/2) Extreme-Duty VAP Valves

Picture for category 7 Family - 4 Way (5/2) Extreme-Duty VAP Valves

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

These time-tested 4-Way valves are used to actuate double acting cylinders and pilot larger process control valves in some of the world's most demanding applications. SIL 3 capable, with service down to -40°F / -40°C, these valves are known for their reliability; plus a myriad of compliant electrical options for North America and rest-of-world (RoW) make these valves a defacto global standard in process control markets.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePricePort TypePort SizeDivisionMaximum Fluid TemperatureMaximum Pressure DifferentialActuation TypeSpecifications MetIngress Protection RatingMinimum Fluid TemperatureBody MaterialInsulation ClassPower ConsumptionInput VoltageMediaCoil TypeValve TypeSeal MaterialMain Flow CoefficientMinimum Pressure DifferentialInstallationOrifice SizeOverride FunctionalityPreventive Maintenance KitMaximum Ambient TemperatureFunctionPort TypeActuation TypeInsulation ClassIngress Protection RatingMaximum Fluid TemperatureMaximum Pressure DifferentialMaximum Ambient TemperatureBody MaterialPort SizePower ConsumptionCoil TypeMediaValve TypeInstallationOrifice SizeInput VoltageSeal MaterialSpecifications MetMain Flow CoefficientMinimum Fluid TemperaturePreventive Maintenance KitMinimum Pressure DifferentialFunctionOverride Functionality
73477VN2PN00N0C111C6
Quote Required
TBD
NPT1/4 inchFluid Control Division150 °F150.0 psiInternal PilotEMCNEMA 4X-40 °FStainless Steel 303F (155°C)10 W120 VDCInert Gases1/2" NPT Conduit with 18" Leads4-Way (5/2)NBR - Low Temp1.2 Cv30 psiIOM 77011/4 inchn/a7K701167 °FDual SolenoidNPTInternally PilotedClass FNEMA 4,4X150.0150.0167.0303 Stainless Steel1/410.01/2" NPT Conduit with 18" LeadsAir, Inert Gas4 Way (5/2)IOM 77011/4120.0NBR - Low TempUL, CSA Listed General Purpose Valve; SIL 3; CE - Low Voltage, EMC1.2-40.07K70130.02 Position, Dual Solenoid
73477VN2PN00N0H222P3
Quote Required
TBD
NPT1/4 inchFluid Control Division150 °F150.0 psiInternal PilotCSA listed General Purpose Valve for Hazardous Locations; SIL 3; CE - Low VoltageCSA Class 2, Div. 1, Group E,F,G to T3C-40 °FStainless Steel 303H (180°C)10 W110/50 VACAir1/2" NPT Conduit with 18" Leads4-Way (5/2)NBR - Low Temp1.2 Cv30 psiIOM 77011/4 inchn/a7K701167 °FDual SolenoidNPTInternally PilotedClass HUL, CSA - Class 1, Div. 1, Group A,B,C,D Class 2, Div. 1, Group E,F,G - T3C150.0150.0167.0303 Stainless Steel1/410.01/2" NPT Conduit with 18" LeadsAir, Inert Gas4 Way (5/2)IOM 77011/4120/60, 110/50NBR - Low TempUL, CSA Listed General Purpose Valve for Hazardous Locations; SIL 3; CE - Low Voltage, EMC1.2-40.07K70130.02 Position, Dual Solenoid
73477VN2PN00N0H611C2
Quote Required
TBD
NPT1/4 inchFluid Control Division150 °F150.0 psiInternal PilotCSA listed General Purpose Valve for Hazardous Locations; SIL 3; CE - Low VoltageCSA Class 2, Div. 1, Group E,F,G to T3C-40 °FStainless Steel 303F (155°C)1.5 W24 VDCAir1/2" NPT Conduit with 18" Leads4-Way (5/2)NBR - Low Temp1.2 Cv30 psiIOM 77011/4 inchn/a7K701167 °FDual SolenoidNPTInternally PilotedClass FUL, CSA - Class 1, Div. 1, Group A,B,C,D Class 2, Div. 1, Group E,F,G - T3C150.0150.0167.0303 Stainless Steel1/41.51/2" NPT Conduit with 18" LeadsAir, Inert Gas4 Way (5/2)IOM 77011/424.0NBR - Low TempUL, CSA Listed General Purpose Valve for Hazardous Locations; SIL 3; CE - Low Voltage, EMC1.2-40.07K70130.02 Position, Dual Solenoid
73477VN2PNM0N0C222C2
Quote Required
TBD
NPT1/4 inchFluid Control Division150 °F150.0 psiInternal PilotEMCNEMA 4X-40 °FStainless Steel 303H (180°C)10 W24 VDCInert Gases1/2" NPT Conduit with 18" Leads4-Way (5/2)NBR - Low Temp1.2 Cv30 psiIOM 77011/4 inchLocking Manual Override7K701167 °FDual SolenoidNPTInternally PilotedClass HNEMA 4,4X150.0150.0167.0303 Stainless Steel1/410.01/2" NPT Conduit with 18" LeadsAir, Inert Gas4 Way (5/2)IOM 77011/424.0NBR - Low TempUL, CSA Listed General Purpose Valve; SIL 3; CE - Low Voltage, EMC1.2-40.07K70130.02 Position, Dual SolenoidLocking Manual Override
73477VN2PNM0N0D200C2
Quote Required
TBD
NPT1/4 inchFluid Control Division150 °F150.0 psiInternal PilotCSA listed General Purpose Valve; SIL 3; CE - Low VoltageNEMA 4-40 °FStainless Steel 303F (155°C)10 W24 VDCInert GasesDIN 43650A / ISO 44004-Way (5/2)NBR - Low Temp1.2 Cv30 psiIOM 75051/4 inchLocking Manual Override7K701167 °FDual SolenoidNPTInternally PilotedClass FNEMA 4,4X150.0150.0167.0303 Stainless Steel1/410.0DIN 43650A / ISO 4400Air, Inert Gas4 Way (5/2)IOM 77011/424.0NBR - Low TempUL, CSA Listed General Purpose Valve; SIL 3; CE - Low Voltage, EMC1.2-40.07K70130.02 Position, Dual SolenoidLocking Manual Override