• Availability & Price
  • Search SKU
Filter by attributes
  • Body Style
  • Body/Elastomer Materials
  • Electrical Connection
  • Maximum Operating Pressure/Orifice Size
  • Maximum Operating Voltage
  • Pneumatic Connection
  • Trade Name
  • Series
  • Material
  • Configuration Type
More Filters...
Filter by manufacturer
Manufacturers

55 Series 10655

Picture for category 55 Series 10655

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker Parflex 55 Series Permanent, Hose X Female JIC Swivel Fittings for thermoplastic hose. Many Fitting Configurations are available in Stainless Steel, Steel and Brass.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceSeal MaterialFor Fluid TypeConfigurationMaximum Operating TemperatureFunctionActuation TypeMinimum Operating TemperatureDivisionOperation TypeControl MethodMax Order QuantityStandard Lead TimeOut of Stock Lead TimeMaximum Operating PressureShipping WeightLeak RateIndustry ApplicationMaximum Flow RateLengthWeightWidthInput VoltageConnection SizeCycles per LifetimeThermal CompensationElectrical ConnectionHeightBody MaterialConnection TypePower ConsumptionVacuum to Pressure RangeFlow RateOrifice SizeBody StylePneumatic ConnectionElectrical ConnectionMaximum Operating VoltageBody/Elastomer MaterialsMaximum Operating Pressure/Orifice SizeMounting Type
910-000046-217
Quote Required
TBD
FKMGasesn/a131 °F2-WaySolenoid32 °FPrecision Fluidics DivisionElectronicCurrent or Voltage920406.89 bar0.35< 0.016 cm3/min of Helium @ 150 PsiMass Flow Control50 SLPM1.79 inch63 g15.9 mm11.5 VDC4-40 x 5/8" Pan Head Phillips Screw100 MillionThermally CompensatedQuick Spade17.0 mmStainless Steel 300 SeriesManifold Mount with Screens2.0 W Maximum27 Inch-Hg to Pressure Rating50 SLPM1.27 mmManifold MountSquare Body(Manifold and Barb)Quick Spade11.5 VDCStainless Steel/FKM100 psid/.050"
910-000046-220
Quote Required
TBD
FKMGasesn/a55 °C2-WaySolenoid32 °FPrecision Fluidics DivisionElectronicCurrent or Voltage92040100 psi0.35< 0.016 cm3/min of Helium @ 150 PsiMass Flow Control50 SLPM45.3 mm2.2 oz15.9 mm13.5 VDC4-40 x 5/8" Pan Head Phillips Screw100 MillionThermally Compensated18" Wire Leads17.0 mmStainless Steel 300 SeriesManifold Mount with Screens2.0 W Maximum686.0 mm-Hg to Pressure Rating50 SLPM0.050 inchManifold MountSquare Body(Manifold and Barb)18" Wire Leads13.5 VDCStainless Steel/FKM100 psid/.050"
910-000046-221
Quote Required
TBD
FKMGasesn/a131 °F2-WaySolenoid0 °CPrecision Fluidics DivisionElectronicCurrent or Voltage92040100 psi0.35< 0.016 cm3/min of Helium @ 150 PsiPressure & Flow Control50 SLPM1.79 inch2.2 oz15.9 mm13.5 VDC1/8 inch Barb for I.D. Tubing100 MillionThermally Compensated18" Wire Leads0.67 inchStainless Steel 300 SeriesBarb2.0 W Maximum686.0 mm-Hg to Pressure Rating50 SLPM1.27 mmManifold Mount w/ ScreensSquare Body(Manifold and Barb)18" Wire Leads13.5 VDCStainless Steel/FKM100 psid/.050"Mounting Screw
910-000046-231
Quote Required
TBD
FKMGasesn/a131 °F2-WaySolenoid32 °FPrecision Fluidics DivisionElectronicCurrent or Voltage92040100 psi0.35< 0.016 cm3/min of Helium @ 150 PsiAnesthesia Delivery50 SLPM45.3 mm63 g0.63 inch20 VDC4-40 x 5/8" Pan Head Phillips Screw100 MillionThermally Compensated18" Wire Leads17.0 mmStainless Steel 300 SeriesManifold Mount2.0 W Maximum686.0 mm-Hg to Pressure Rating50 SLPM0.050 inch1/8" BarbsSquare Body(Manifold and Barb)18" Wire Leads20 VDCStainless Steel/FKM100 psid/.050"Mounting Screw
910-000046-265
Quote Required
TBD
FFKMGasesn/a55 °CNormally Closed (NC)Solenoid0 °CPrecision Fluidics DivisionElectronicCurrent or Voltage920406.89 bar0.35< 0.016 cm3/min of Helium @ 150 PsiAnesthesia Delivery50 SLPM1.79 inch63 g0.63 inch5.5 VDC4-40 x 5/8" Pan Head Phillips Screw100 MillionThermally Compensated18" Wire Leads17.0 mmStainless Steel 300 SeriesManifold Mount with Screens2.0 W Maximum686.0 mm-Hg to Pressure Rating50 SLPM1.27 mmManifold MountSquare Body(Manifold and Barb)18" Wire Leads5.5 VDCStainless Steel/FFKM100 psid/.050"Mounting Screw
910-000046-271
Quote Required
TBD
FFKMGasesn/a55 °CNormally Closed (NC)Solenoid0 °CPrecision Fluidics DivisionElectronicCurrent or Voltage920406.89 bar0.35< 0.016 cm3/min of Helium @ 150 PsiPressure & Flow Control50 SLPM45.3 mm2.2 oz15.9 mm5.5 VDC4-40 x 5/8" Pan Head Phillips Screw100 MillionThermally CompensatedQuick Spade0.67 inchStainless Steel 300 SeriesManifold Mount with Screens2.0 W Maximum27 Inch-Hg to Pressure Rating50 SLPM1.27 mmManifold MountSquare Body(Manifold and Barb)Quick Spade5.5 VDCStainless Steel/FFKM100 psid/.050"Mounting Screw
910-000046-276
Quote Required
TBD
FFKMGasesn/a55 °CNormally Closed (NC)Solenoid32 °FPrecision Fluidics DivisionElectronicCurrent or Voltage92040100 psi0.35< 0.016 cm3/min of Helium @ 150 PsiGas Chromatography50 SLPM45.3 mm63 g15.9 mm8 VDC4-40 x 5/8" Pan Head Phillips Screw100 MillionThermally Compensated18" Wire Leads0.67 inchStainless Steel 300 SeriesManifold Mount2.0 W Maximum686.0 mm-Hg to Pressure Rating50 SLPM1.27 mm1/8" BarbsSquare Body(Manifold and Barb)18" Wire Leads8 VDCStainless Steel/FFKM100 psid/.050"Mounting Screw
910-000046-291
Quote Required
TBD
FFKMGasesn/a131 °FNormally Closed (NC)Solenoid32 °FPrecision Fluidics DivisionElectronicCurrent or Voltage920406.89 bar0.35< 0.016 cm3/min of Helium @ 150 PsiMass Flow Control50 SLPM45.3 mm63 g0.63 inch11.5 VDC4-40 x 5/8" Pan Head Phillips Screw100 MillionThermally Compensated18" Wire Leads0.67 inchStainless Steel 300 SeriesManifold Mount2.0 W Maximum686.0 mm-Hg to Pressure Rating50 SLPM0.050 inch1/8" BarbsSquare Body(Manifold and Barb)Quick Spade11.5 VDCStainless Steel/FFKM100 psid/.050"Mounting Screw
910-000046-292
Quote Required
TBD
FFKMGasesn/a131 °FNormally Closed (NC)Solenoid0 °CPrecision Fluidics DivisionElectronicCurrent or Voltage920406.89 bar0.35< 0.016 cm3/min of Helium @ 150 PsiAnesthesia Delivery50 SLPM1.79 inch63 g0.63 inch13.5 VDC4-40 x 5/8" Pan Head Phillips Screw100 MillionThermally Compensated18" Wire Leads17.0 mmStainless Steel 300 SeriesManifold Mount with Screens2.0 W Maximum686.0 mm-Hg to Pressure Rating50 SLPM0.050 inchManifold MountSquare Body(Manifold and Barb)18" Wire Leads13.5 VDCStainless Steel/FFKM100 psid/.050"Mounting Screw
910-000046-293
Quote Required
TBD
FFKMGasesn/a131 °F2-WaySolenoid0 °CPrecision Fluidics DivisionElectronicCurrent or Voltage920406.89 bar0.35< 0.016 cm3/min of Helium @ 150 PsiPressure & Flow Control50 SLPM1.79 inch2.2 oz15.9 mm13.5 VDC1/8 inch Barb for I.D. Tubing100 MillionThermally Compensated18" Wire Leads17.0 mmStainless Steel 300 SeriesBarb2.0 W Maximum686.0 mm-Hg to Pressure Rating50 SLPM0.050 inchManifold Mount w/ ScreensSquare Body(Manifold and Barb)18" Wire Leads13.5 VDCStainless Steel/FFKM100 psid/.050"Mounting Screw
910-000047-001
Quote Required
TBD
FKMGasesn/a131 °F2-WaySolenoid32 °FPrecision Fluidics DivisionElectronicCurrent or Voltage9204050 psi0.35< 0.016 cm3/min of Helium @ 150 PsiVentilators33 SLPM45.3 mm63 g15.9 mm5.5 VDC4-40 x 5/8" Pan Head Phillips Screw100 MillionThermally Compensated18" Wire Leads17.0 mmBrass 360 H02Manifold Mount2.0 W Maximum27 Inch-Hg to Pressure Rating33 SLPM1.65 mmManifold MountSquare Body(Manifold and Barb)18" Wire Leads5.5 VDCBrass/FKM50 psid/.065"Mounting Screw
910-000047-002
Quote Required
TBD
FKMGasesn/a131 °FNormally Closed (NC)Solenoid32 °FPrecision Fluidics DivisionElectronicCurrent or Voltage9204050 psi0.35< 0.016 cm3/min of Helium @ 150 PsiAnesthesia Delivery33 SLPM1.79 inch63 g0.63 inch5.5 VDC4-40 x 5/8" Pan Head Phillips Screw100 MillionThermally Compensated18" Wire Leads17.0 mmBrass 360 H02Manifold Mount with Screens2.0 W Maximum27 Inch-Hg to Pressure Rating33 SLPM0.065 inchManifold Mount w/ ScreensSquare Body(Manifold and Barb)18" Wire Leads5.5 VDCBrass/FKM50 psid/.065"Mounting Screw
910-000047-003
Quote Required
TBD
FKMGasesn/a131 °FNormally Closed (NC)Solenoid32 °FPrecision Fluidics DivisionElectronicCurrent or Voltage920403.45 bar0.35< 0.016 cm3/min of Helium @ 150 PsiOxygen Conservers & Concentrators33 SLPM1.79 inch2.2 oz15.9 mm5.5 VDC1/8 inch Barb for I.D. Tubing100 MillionThermally Compensated4-Pin PCB17.0 mmBrass 360 H02Barb2.0 W Maximum686.0 mm-Hg to Pressure Rating33 SLPM0.065 inch1/8" BarbsSquare Body(Manifold and Barb)18" Wire Leads5.5 VDCBrass/FKM50 psid/.065"Mounting Screw
910-000047-004
Quote Required
TBD
FKMGasesn/a55 °CNormally Closed (NC)Solenoid32 °FPrecision Fluidics DivisionElectronicCurrent or Voltage9204050 psi0.35< 0.016 cm3/min of Helium @ 150 PsiGas Chromatography33 SLPM1.79 inch2.2 oz0.63 inch5.5 VDC4-40 x 5/8" Pan Head Phillips Screw100 MillionThermally Compensated4-Pin PCB17.0 mmBrass 360 H02Manifold Mount2.0 W Maximum27 Inch-Hg to Pressure Rating33 SLPM1.65 mmManifold MountSquare Body(Manifold and Barb)PC Board Mount5.5 VDCBrass/FKM50 psid/.065"Mounting Screw
910-000047-006
Quote Required
TBD
FKMGasesn/a55 °C2-WaySolenoid32 °FPrecision Fluidics DivisionElectronicCurrent or Voltage9204050 psi0.35< 0.016 cm3/min of Helium @ 150 PsiMass Flow Control33 SLPM45.3 mm2.2 oz15.9 mm5.5 VDC1/8 inch Barb for I.D. Tubing100 MillionThermally CompensatedQuick Spade0.67 inchBrass 360 H02Barb2.0 W Maximum686.0 mm-Hg to Pressure Rating33 SLPM1.65 mm1/8" BarbsSquare Body(Manifold and Barb)PC Board Mount5.5 VDCBrass/FKM50 psid/.065"Mounting Screw
910-000047-007
Quote Required
TBD
FKMGasesn/a131 °FNormally Closed (NC)Solenoid0 °CPrecision Fluidics DivisionElectronicCurrent or Voltage920403.45 bar0.35< 0.016 cm3/min of Helium @ 150 PsiPressure & Flow Control33 SLPM1.79 inch63 g0.63 inch5.5 VDC4-40 x 5/8" Pan Head Phillips Screw100 MillionThermally CompensatedQuick Spade17.0 mmBrass 360 H02Manifold Mount2.0 W Maximum686.0 mm-Hg to Pressure Rating33 SLPM0.065 inchManifold MountSquare Body(Manifold and Barb)Quick Spade5.5 VDCBrass/FKM50 psid/.065"Mounting Screw
910-000047-009
Quote Required
TBD
FKMGasesn/a131 °FNormally Closed (NC)Solenoid32 °FPrecision Fluidics DivisionElectronicCurrent or Voltage920403.45 bar0.35< 0.016 cm3/min of Helium @ 150 PsiAnesthesia Delivery33 SLPM45.3 mm63 g0.63 inch5.5 VDC1/8 inch Barb for I.D. Tubing100 MillionThermally Compensated18" Wire Leads0.67 inchBrass 360 H02Barb2.0 W Maximum686.0 mm-Hg to Pressure Rating33 SLPM0.065 inch1/8" BarbsSquare Body(Manifold and Barb)Quick Spade5.5 VDCBrass/FKM50 psid/.065"Mounting Screw
910-000047-010
Quote Required
TBD
FKMGasesn/a131 °F2-WaySolenoid0 °CPrecision Fluidics DivisionElectronicCurrent or Voltage9204050 psi0.35< 0.016 cm3/min of Helium @ 150 PsiPressure & Flow Control33 SLPM45.3 mm2.2 oz15.9 mm8 VDC4-40 x 5/8" Pan Head Phillips Screw100 MillionThermally Compensated18" Wire Leads17.0 mmBrass 360 H02Manifold Mount2.0 W Maximum686.0 mm-Hg to Pressure Rating33 SLPM0.065 inchManifold MountSquare Body(Manifold and Barb)18" Wire Leads8 VDCBrass/FKM50 psid/.065"Mounting Screw
910-000047-011
Quote Required
TBD
FKMGasesn/a55 °C2-WaySolenoid0 °CPrecision Fluidics DivisionElectronicCurrent or Voltage9204050 psi0.35< 0.016 cm3/min of Helium @ 150 PsiAnesthesia Delivery33 SLPM45.3 mm2.2 oz0.63 inch8 VDC4-40 x 5/8" Pan Head Phillips Screw100 MillionThermally Compensated18" Wire Leads17.0 mmBrass 360 H02Manifold Mount with Screens2.0 W Maximum27 Inch-Hg to Pressure Rating33 SLPM1.65 mmManifold Mount w/ ScreensSquare Body(Manifold and Barb)18" Wire Leads8 VDCBrass/FKM50 psid/.065"Mounting Screw
910-000047-012
Quote Required
TBD
FKMGasesn/a131 °F2-WaySolenoid0 °CPrecision Fluidics DivisionElectronicCurrent or Voltage920403.45 bar0.35< 0.016 cm3/min of Helium @ 150 PsiAnaesthesia Delivery & Monitors33 SLPM1.79 inch2.2 oz15.9 mm8 VDC1/8 inch Barb for I.D. Tubing100 MillionThermally Compensated4-Pin PCB0.67 inchBrass 360 H02Barb2.0 W Maximum686.0 mm-Hg to Pressure Rating33 SLPM0.065 inch1/8" BarbsSquare Body(Manifold and Barb)18" Wire Leads8 VDCBrass/FKM50 psid/.065"Mounting Screw