• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Configuration
  • Flow Direction
  • Flow Rate
  • Maximum Inlet Pressure Rating
  • Seal Material
More Filters...
Filter by manufacturer
Manufacturers

4 Way 2 Position Spool Type Solenoid Valve

Picture for category 4 Way 2 Position Spool Type Solenoid Valve

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s direct acting 4-way, 2-position spool-type solenoid valves feature a tough design that ensures reliable and predictable performance with low pressure drop and minimal hysteresis. These valves can operate with hydraulic system flows as high as 113 lpm (30 gpm) and pressures up to 350 bar (5000 psi) with normally passing, crossing, or closed configurations available. Parker’s 4-way, 2-position spool-type solenoid valves are ideal for reversing or actuation applications; utilizing easily wired and programmed solenoid driven directional controls. These valves can be used on a wide range of machinery within the mobile, industrial, or manufacturing markets.

Markets:
• Aerial
• Agriculture
• Construction
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile

Features/Benefits:
• Replaceable one-piece coils with low amp draw
• High flow capacity
• Manual override options
• Standard bodies and cavities
• No dynamic seals
• Low hysteresis
• All external parts zinc plated

Applications:
• Reversing flow
• Actuator applications
• Single direction on/off applications

Additional Technical Insight:
Direct acting spool valves are fast to respond to coil voltage and can quickly re-direct or block flow to actuator ports.  Some leakage will be present due to spool clearances.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceFlow RateSeal MaterialBody MaterialDivisionMaximum Kinematic ViscosityMinimum Operating TemperatureConfigurationWeightCavity SizeMaximum Flow RateFunctionActuation TypeFor Fluid TypeOperation TypeValve MaterialFilter Efficiency RatingOperating TemperatureMaximum Operating TemperatureMounting TypeInput VoltageOverride FunctionalityCoil Nut Tightening TorqueCoil TypeFlow DirectionResponse TimeMaximum Operating PressureMaximum Inlet Pressure RatingInstallation TorqueLeak RateSeal MaterialFlow RateActuation TypeConfigurationFlow DirectionMaximum Inlet Pressure Rating
DSL104E1TV
Quote Required
TBD
10Fluorocarbonn/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-15n/a0.44C10-4104-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-15 to +400+400Screw in cartridge valve85% of rated voltage at 72°F (20°C)Push and Twist5-75/8" Super CoilAll ports blocked De-Energized, 2-1, 3-4 Energized30-603600360037-41230 @ 3600 PSI (250 BAR)Fluorocarbon10 GAL/MIN, 38 L/MINElectrical, ManualN/AAll ports blocked De-Energized, 2-1, 3-4 Energized3600 PSI, 250 BAR
DSL104E1V
Quote Required
TBD
10Fluorocarbonn/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-15n/a0.44C10-4104-WayElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-15 to +400+400Screw in cartridge valve85% of rated voltage at 72°F (20°C)n/a5-75/8" Super CoilAll ports blocked De-Energized, 2-1, 3-4 Energized30-603600360037-41230 @ 3600 PSI (250 BAR)Fluorocarbon10 GAL/MIN, 38 L/MINElectricalN/AAll ports blocked De-Energized, 2-1, 3-4 Energized3600 PSI, 250 BAR
DSL104E4
Quote Required
TBD
8 Gal/minD-Ring (Standard)n/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-35 °Fn/a0.2 kgC10-48 Gal/min4-WayElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-35 to +200 °F+200 °FScrew in cartridge valve85% of rated voltage at 72°F (20°C) minn/a5-7 lb-ft5/8" Super Coil3 blocked, 2-4-1 De-Energized, 2-1, 3-4 Energized30-60 ms250 bar250 bar37-41 lb-ft230 @ 3600 PSI (250 BAR) cm3/minD-Ring (Standard)8 GAL/MIN, 30 L/MINElectricalN/A3 blocked, 2-4-1 De-Energized, 2-1, 3 and 4 blocked Energized3600 PSI, 250 BAR
DSL104E4N
Quote Required
TBD
30 L/minNitrilen/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-34 °Cn/a0.44 lbC10-48 Gal/min4-WayElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-34 to +121 °C+250 °FScrew in cartridge valve85% of rated voltage at 72°F (20°C) minn/a5-7 lb-ft5/8" Super Coil3 blocked, 2-4-1 De-Energized, 2-1, 3-4 Energized30-60 ms3600 psi3600 psi50-56 Nm230 @ 3600 PSI (250 BAR) cm3/minNitrile8 GAL/MIN, 30 L/MINElectricalN/A3 blocked, 2-4-1 De-Energized, 2-1, 3 and 4 blocked Energized3600 PSI, 250 BAR
DSL104E4P
Quote Required
TBD
8D-Ring (Standard)n/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-35n/a0.44C10-484-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-35 to +200+200Screw in cartridge valve85% of rated voltage at 72°F (20°C)Pull and Release5-75/8" Super Coil3 blocked, 2-4-1 De-Energized, 2-1, 3-4 Energized30-603600360037-41230 @ 3600 PSI (250 BAR)D-Ring (Standard)8 GAL/MIN, 30 L/MINElectrical, ManualN/A3 blocked, 2-4-1 De-Energized, 2-1, 3 and 4 blocked Energized3600 PSI, 250 BAR
DSL104E4PN
Quote Required
TBD
30 L/minNitrilen/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-34 °Cn/a0.44 lbC10-430 L/min4-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-34 to +121 °C+250 °FScrew in cartridge valve85% of rated voltage at 72°F (20°C) minPull and Release7-10 Nm5/8" Super Coil3 blocked, 2-4-1 De-Energized, 2-1, 3-4 Energized30-60 ms3600 psi3600 psi50-56 Nm230 @ 3600 PSI (250 BAR) cm3/minNitrile8 GAL/MIN, 30 L/MINElectrical, ManualN/A3 blocked, 2-4-1 De-Energized, 2-1, 3 and 4 blocked Energized3600 PSI, 250 BAR
DSL104E4PV
Quote Required
TBD
8Fluorocarbonn/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-15n/a0.44C10-484-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-15 to +400+400Screw in cartridge valve85% of rated voltage at 72°F (20°C)Pull and Release5-75/8" Super Coil3 blocked, 2-4-1 De-Energized, 2-1, 3-4 Energized30-603600360037-41230 @ 3600 PSI (250 BAR)Fluorocarbon8 GAL/MIN, 30 L/MINElectrical, ManualN/A3 blocked, 2-4-1 De-Energized, 2-1, 3 and 4 blocked Energized3600 PSI, 250 BAR
DSL104E4T
Quote Required
TBD
8 Gal/minD-Ring (Standard)n/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-35 °Fn/a0.2 kgC10-48 Gal/min4-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-37 to +93 °C+200 °FScrew in cartridge valve85% of rated voltage at 72°F (20°C) minPush and Twist5-7 lb-ft5/8" Super Coil3 blocked, 2-4-1 De-Energized, 2-1, 3-4 Energized30-60 ms3600 psi3600 psi37-41 lb-ft230 @ 3600 PSI (250 BAR) cm3/minD-Ring (Standard)8 GAL/MIN, 30 L/MINElectrical, ManualN/A3 blocked, 2-4-1 De-Energized, 2-1, 3 and 4 blocked Energized3600 PSI, 250 BAR
DSL104E4TN
Quote Required
TBD
8Nitrilen/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-30n/a0.44C10-484-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-30 to +250+250Screw in cartridge valve85% of rated voltage at 72°F (20°C)Push and Twist5-75/8" Super Coil3 blocked, 2-4-1 De-Energized, 2-1, 3-4 Energized30-603600360037-41230 @ 3600 PSI (250 BAR)Nitrile8 GAL/MIN, 30 L/MINElectrical, ManualN/A3 blocked, 2-4-1 De-Energized, 2-1, 3 and 4 blocked Energized3600 PSI, 250 BAR
DSL104E4TV
Quote Required
TBD
8 Gal/minFluorocarbonn/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-15 °Fn/a0.2 kgC10-48 Gal/min4-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-15 to +400 °F+400 °FScrew in cartridge valve85% of rated voltage at 72°F (20°C) minPush and Twist7-10 Nm5/8" Super Coil3 blocked, 2-4-1 De-Energized, 2-1, 3-4 Energized30-60 ms3600 psi250 bar37-41 lb-ft230 @ 3600 PSI (250 BAR) cm3/minFluorocarbon8 GAL/MIN, 30 L/MINElectrical, ManualN/A3 blocked, 2-4-1 De-Energized, 2-1, 3 and 4 blocked Energized3600 PSI, 250 BAR
DSL104E4V
Quote Required
TBD
8Fluorocarbonn/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-15n/a0.44C10-484-WayElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-15 to +400+400Screw in cartridge valve85% of rated voltage at 72°F (20°C)n/a5-75/8" Super Coil3 blocked, 2-4-1 De-Energized, 2-1, 3-4 Energized30-603600360037-41230 @ 3600 PSI (250 BAR)Fluorocarbon8 GAL/MIN, 30 L/MINElectricalN/A3 blocked, 2-4-1 De-Energized, 2-1, 3 and 4 blocked Energized3600 PSI, 250 BAR
DSL104H
Quote Required
TBD
27 L/minD-Ring (Standard)n/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-37 °Cn/a0.2 kgC10-47 Gal/min4-WayElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-35 to +200 °F+200 °FScrew in cartridge valve85% of rated voltage at 72°F (20°C) minn/a5-7 lb-ft5/8" Super Coil2-1, 3-4 De-Energized, 3-2, 4-1 Energized30-60 ms3600 psi3600 psi37-41 lb-ft230 @ 3600 PSI (250 BAR) cm3/minD-Ring (Standard)7 GAL/MIN, 27 L/MINElectricalN/A2-1, 3-4 De-Energized, 3-2, 4-1 Energized3600 PSI, 250 BAR
DSL104HN
Quote Required
TBD
27 L/minNitrilen/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-34 °Cn/a0.2 kgC10-427 L/min4-WayElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-30 to +250 °F+121 °CScrew in cartridge valve85% of rated voltage at 72°F (20°C) minn/a5-7 lb-ft5/8" Super Coil2-1, 3-4 De-Energized, 3-2, 4-1 Energized30-60 ms3600 psi250 bar37-41 lb-ft230 @ 3600 PSI (250 BAR) cm3/minNitrile7 GAL/MIN, 27 L/MINElectricalN/A2-1, 3-4 De-Energized, 3-2, 4-1 Energized3600 PSI, 250 BAR
DSL104HP
Quote Required
TBD
7D-Ring (Standard)n/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-35n/a0.44C10-474-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-35 to +200+200Screw in cartridge valve85% of rated voltage at 72°F (20°C)Pull and Release5-75/8" Super Coil2-1, 3-4 De-Energized, 3-2, 4-1 Energized30-603600360037-41230 @ 3600 PSI (250 BAR)D-Ring (Standard)7 GAL/MIN, 27 L/MINElectrical, ManualN/A2-1, 3-4 De-Energized, 3-2, 4-1 Energized3600 PSI, 250 BAR
DSL104HPN
Quote Required
TBD
7Nitrilen/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-30n/a0.44C10-474-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-30 to +250+250Screw in cartridge valve85% of rated voltage at 72°F (20°C)Pull and Release5-75/8" Super Coil2-1, 3-4 De-Energized, 3-2, 4-1 Energized30-603600360037-41230 @ 3600 PSI (250 BAR)Nitrile7 GAL/MIN, 27 L/MINElectrical, ManualN/A2-1, 3-4 De-Energized, 3-2, 4-1 Energized3600 PSI, 250 BAR
DSL104HPV
Quote Required
TBD
7Fluorocarbonn/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-15n/a0.44C10-474-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-15 to +400+400Screw in cartridge valve85% of rated voltage at 72°F (20°C)Pull and Release5-75/8" Super Coil2-1, 3-4 De-Energized, 3-2, 4-1 Energized30-603600360037-41230 @ 3600 PSI (250 BAR)Fluorocarbon7 GAL/MIN, 27 L/MINElectrical, ManualN/A2-1, 3-4 De-Energized, 3-2, 4-1 Energized3600 PSI, 250 BAR
DSL104HT
Quote Required
TBD
27 L/minD-Ring (Standard)n/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-37 °Cn/a0.2 kgC10-427 L/min4-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-37 to +93 °C+200 °FScrew in cartridge valve85% of rated voltage at 72°F (20°C) minPush and Twist5-7 lb-ft5/8" Super Coil2-1, 3-4 De-Energized, 3-2, 4-1 Energized30-60 ms250 bar3600 psi37-41 lb-ft230 @ 3600 PSI (250 BAR) cm3/minD-Ring (Standard)7 GAL/MIN, 27 L/MINElectrical, ManualN/A2-1, 3-4 De-Energized, 3-2, 4-1 Energized3600 PSI, 250 BAR
DSL104HTN
Quote Required
TBD
7Nitrilen/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-30n/a0.44C10-474-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-30 to +250+250Screw in cartridge valve85% of rated voltage at 72°F (20°C)Push and Twist5-75/8" Super Coil2-1, 3-4 De-Energized, 3-2, 4-1 Energized30-603600360037-41230 @ 3600 PSI (250 BAR)Nitrile7 GAL/MIN, 27 L/MINElectrical, ManualN/A2-1, 3-4 De-Energized, 3-2, 4-1 Energized3600 PSI, 250 BAR
DSL104HTV
Quote Required
TBD
7Fluorocarbonn/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-15n/a0.44C10-474-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-15 to +400+400Screw in cartridge valve85% of rated voltage at 72°F (20°C)Push and Twist5-75/8" Super Coil2-1, 3-4 De-Energized, 3-2, 4-1 Energized30-603600360037-41230 @ 3600 PSI (250 BAR)Fluorocarbon7 GAL/MIN, 27 L/MINElectrical, ManualN/A2-1, 3-4 De-Energized, 3-2, 4-1 Energized3600 PSI, 250 BAR
DSL104HV
Quote Required
TBD
7Fluorocarbonn/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-15n/a0.44C10-474-WayElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-15 to +400+400Screw in cartridge valve85% of rated voltage at 72°F (20°C)n/a5-75/8" Super Coil2-1, 3-4 De-Energized, 3-2, 4-1 Energized30-603600360037-41230 @ 3600 PSI (250 BAR)Fluorocarbon7 GAL/MIN, 27 L/MINElectricalN/A2-1, 3-4 De-Energized, 3-2, 4-1 Energized3600 PSI, 250 BAR