Parker’s direct acting 4-way, 2-position spool-type solenoid valves feature a tough design that ensures reliable and predictable performance with low pressure drop and minimal hysteresis. These valves can operate with hydraulic system flows as high as 113 lpm (30 gpm) and pressures up to 350 bar (5000 psi) with normally passing, crossing, or closed configurations available. Parker’s 4-way, 2-position spool-type solenoid valves are ideal for reversing or actuation applications; utilizing easily wired and programmed solenoid driven directional controls. These valves can be used on a wide range of machinery within the mobile, industrial, or manufacturing markets.

Markets:
• Aerial
• Agriculture
• Construction
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile

Features/Benefits:
• Replaceable one-piece coils with low amp draw
• High flow capacity
• Manual override options
• Standard bodies and cavities
• No dynamic seals
• Low hysteresis
• All external parts zinc plated

Applications:
• Reversing flow
• Actuator applications
• Single direction on/off applications

Additional Technical Insight:
Direct acting spool valves are fast to respond to coil voltage and can quickly re-direct or block flow to actuator ports.  Some leakage will be present due to spool clearances.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceUOMBody MaterialDivisionMaximum Kinematic ViscosityMinimum Operating TemperatureConfigurationWeightFlow RateSeal MaterialCavity SizeMaximum Flow RateFunctionActuation TypeFor Fluid TypeOperation TypeValve MaterialFilter Efficiency RatingMounting TypeOperating TemperatureMaximum Operating TemperatureInput VoltageOverride FunctionalityCoil Nut Tightening TorqueFlow DirectionCoil TypeResponse TimeMaximum Operating PressureMaximum Inlet Pressure RatingInstallation TorqueLeak RateSeal MaterialFlow RateActuation TypeConfigurationFlow DirectionMaximum Inlet Pressure Rating
DSL104BT
Quote Required
$95.81
EAn/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-35 °Fn/a0.2 kg10 Gal/minD-Ring (Standard)C10-410 Gal/min4-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-35 to +200 °F+93 °C85% of rated voltage at 72°F (20°C) minPush and Twist5-7 lb-ft3-2, 4-1 De-Energized, 2-1, 3-4 Energized5/8" Super Coil30-60 ms3600 psi250 bar37-41 lb-ft230 @ 3600 PSI (250 BAR) cm3/minD-Ring (Standard)10 GAL/MIN, 38 L/MINElectrical, ManualN/A3-2, 4-1 De-Energized, 2-1, 3-4 Energized3600 PSI, 250 BAR
DSL104BTN
Quote Required
TBD
n/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-30n/a0.4410NitrileC10-4104-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-30 to +250+25085% of rated voltage at 72°F (20°C)Push and Twist5-73-2, 4-1 De-Energized, 2-1, 3-4 Energized5/8" Super Coil30-603600360037-41230 @ 3600 PSI (250 BAR)Nitrile10 GAL/MIN, 38 L/MINElectrical, ManualN/A3-2, 4-1 De-Energized, 2-1, 3-4 Energized3600 PSI, 250 BAR
DSL104BTV
Quote Required
TBD
n/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-15 °Fn/a0.44 lb10 Gal/minFluorocarbonC10-438 L/min4-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-15 to +400 °F+400 °F85% of rated voltage at 72°F (20°C) minPush and Twist7-10 Nm3-2, 4-1 De-Energized, 2-1, 3-4 Energized5/8" Super Coil30-60 ms250 bar3600 psi50-56 Nm230 @ 3600 PSI (250 BAR) cm3/minFluorocarbon10 GAL/MIN, 38 L/MINElectrical, ManualN/A3-2, 4-1 De-Energized, 2-1, 3-4 Energized3600 PSI, 250 BAR
DSL104BV
Quote Required
250 In Stock
$67.50
EAn/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-26 °Cn/a0.2 kg38 L/minFluorocarbonC10-438 L/min4-WayElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-15 to +400 °F+400 °F85% of rated voltage at 72°F (20°C) minn/a5-7 lb-ft3-2, 4-1 De-Energized, 2-1, 3-4 Energized5/8" Super Coil30-60 ms250 bar250 bar50-56 Nm230 @ 3600 PSI (250 BAR) cm3/minFluorocarbon10 GAL/MIN, 38 L/MINElectricalN/A3-2, 4-1 De-Energized, 2-1, 3-4 Energized3600 PSI, 250 BAR
DSL104E1
Quote Required
TBD
n/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-35 °Fn/a0.2 kg38 L/minD-Ring (Standard)C10-410 Gal/min4-WayElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-35 to +200 °F+93 °C85% of rated voltage at 72°F (20°C) minn/a7-10 NmAll ports blocked De-Energized, 2-1, 3-4 Energized5/8" Super Coil30-60 ms250 bar3600 psi50-56 Nm230 @ 3600 PSI (250 BAR) cm3/minD-Ring (Standard)10 GAL/MIN, 38 L/MINElectricalN/AAll ports blocked De-Energized, 2-1, 3-4 Energized3600 PSI, 250 BAR
DSL104E15
Quote Required
TBD
n/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-37 °Cn/a0.44 lb38 L/minD-Ring (Standard)C10-438 L/min4-WayElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-37 to +93 °C+93 °C85% of rated voltage at 72°F (20°C) minn/a7-10 Nm2-3 blocked, 4-1 De-Energized, 2-1, 3-4 Energized5/8" Super Coil30-60 ms250 bar3600 psi50-56 Nm230 @ 3600 PSI (250 BAR) cm3/minD-Ring (Standard)10 GAL/MIN, 38 L/MINElectricalN/A2-3 blocked, 4-1 De-Energized, 2-1, 3-4 Energized3600 PSI, 250 BAR
DSL104E15N
Quote Required
TBD
n/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-30n/a0.4410NitrileC10-4104-WayElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-30 to +250+25085% of rated voltage at 72°F (20°C)n/a5-72-3 blocked, 4-1 De-Energized, 2-1, 3-4 Energized5/8" Super Coil30-603600360037-41230 @ 3600 PSI (250 BAR)Nitrile10 GAL/MIN, 38 L/MINElectricalN/A2-3 blocked, 4-1 De-Energized, 2-1, 3-4 Energized3600 PSI, 250 BAR
DSL104E15P
Quote Required
TBD
n/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-37 °Cn/a0.44 lb38 L/minD-Ring (Standard)C10-410 Gal/min4-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-37 to +93 °C+200 °F85% of rated voltage at 72°F (20°C) minPull and Release5-7 lb-ft2-3 blocked, 4-1 De-Energized, 2-1, 3-4 Energized5/8" Super Coil30-60 ms3600 psi3600 psi50-56 Nm230 @ 3600 PSI (250 BAR) cm3/minD-Ring (Standard)10 GAL/MIN, 38 L/MINElectrical, ManualN/A2-3 blocked, 4-1 De-Energized, 2-1, 3-4 Energized3600 PSI, 250 BAR
DSL104E15PN
Quote Required
TBD
n/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-30n/a0.4410NitrileC10-4104-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-30 to +250+25085% of rated voltage at 72°F (20°C)Pull and Release5-72-3 blocked, 4-1 De-Energized, 2-1, 3-4 Energized5/8" Super Coil30-603600360037-41230 @ 3600 PSI (250 BAR)Nitrile10 GAL/MIN, 38 L/MINElectrical, ManualN/A2-3 blocked, 4-1 De-Energized, 2-1, 3-4 Energized3600 PSI, 250 BAR
DSL104E15PV
Quote Required
TBD
n/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-15n/a0.4410FluorocarbonC10-4104-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-15 to +400+40085% of rated voltage at 72°F (20°C)Pull and Release5-72-3 blocked, 4-1 De-Energized, 2-1, 3-4 Energized5/8" Super Coil30-603600360037-41230 @ 3600 PSI (250 BAR)Fluorocarbon10 GAL/MIN, 38 L/MINElectrical, ManualN/A2-3 blocked, 4-1 De-Energized, 2-1, 3-4 Energized3600 PSI, 250 BAR
DSL104E15T
Quote Required
TBD
n/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-35 °Fn/a0.2 kg10 Gal/minD-Ring (Standard)C10-410 Gal/min4-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-37 to +93 °C+200 °F85% of rated voltage at 72°F (20°C) minPush and Twist7-10 Nm2-3 blocked, 4-1 De-Energized, 2-1, 3-4 Energized5/8" Super Coil30-60 ms3600 psi250 bar37-41 lb-ft230 @ 3600 PSI (250 BAR) cm3/minD-Ring (Standard)10 GAL/MIN, 38 L/MINElectrical, ManualN/A2-3 blocked, 4-1 De-Energized, 2-1, 3-4 Energized3600 PSI, 250 BAR
DSL104E15TN
Quote Required
TBD
n/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-30n/a0.4410NitrileC10-4104-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-30 to +250+25085% of rated voltage at 72°F (20°C)Push and Twist5-72-3 blocked, 4-1 De-Energized, 2-1, 3-4 Energized5/8" Super Coil30-603600360037-41230 @ 3600 PSI (250 BAR)Nitrile10 GAL/MIN, 38 L/MINElectrical, ManualN/A2-3 blocked, 4-1 De-Energized, 2-1, 3-4 Energized3600 PSI, 250 BAR
DSL104E15TV
Quote Required
TBD
n/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-15 °Fn/a0.2 kg10 Gal/minFluorocarbonC10-438 L/min4-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-15 to +400 °F+204 °C85% of rated voltage at 72°F (20°C) minPush and Twist7-10 Nm2-3 blocked, 4-1 De-Energized, 2-1, 3-4 Energized5/8" Super Coil30-60 ms3600 psi250 bar37-41 lb-ft230 @ 3600 PSI (250 BAR) cm3/minFluorocarbon10 GAL/MIN, 38 L/MINElectrical, ManualN/A2-3 blocked, 4-1 De-Energized, 2-1, 3-4 Energized3600 PSI, 250 BAR
DSL104E15V
Quote Required
TBD
n/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-15n/a0.4410FluorocarbonC10-4104-WayElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-15 to +400+40085% of rated voltage at 72°F (20°C)n/a5-72-3 blocked, 4-1 De-Energized, 2-1, 3-4 Energized5/8" Super Coil30-603600360037-41230 @ 3600 PSI (250 BAR)Fluorocarbon10 GAL/MIN, 38 L/MINElectricalN/A2-3 blocked, 4-1 De-Energized, 2-1, 3-4 Energized3600 PSI, 250 BAR
DSL104E1N
Quote Required
TBD
n/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-30n/a0.4410NitrileC10-4104-WayElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-30 to +250+25085% of rated voltage at 72°F (20°C)n/a5-7All ports blocked De-Energized, 2-1, 3-4 Energized5/8" Super Coil30-603600360037-41230 @ 3600 PSI (250 BAR)Nitrile10 GAL/MIN, 38 L/MINElectricalN/AAll ports blocked De-Energized, 2-1, 3-4 Energized3600 PSI, 250 BAR
DSL104E1P
Quote Required
TBD
n/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-37 °Cn/a0.44 lb38 L/minD-Ring (Standard)C10-410 Gal/min4-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-35 to +200 °F+200 °F85% of rated voltage at 72°F (20°C) minPull and Release5-7 lb-ftAll ports blocked De-Energized, 2-1, 3-4 Energized5/8" Super Coil30-60 ms3600 psi3600 psi37-41 lb-ft230 @ 3600 PSI (250 BAR) cm3/minD-Ring (Standard)10 GAL/MIN, 38 L/MINElectrical, ManualN/AAll ports blocked De-Energized, 2-1, 3-4 Energized3600 PSI, 250 BAR
DSL104E1PN
Quote Required
TBD
n/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-30n/a0.4410NitrileC10-4104-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-30 to +250+25085% of rated voltage at 72°F (20°C)Pull and Release5-7All ports blocked De-Energized, 2-1, 3-4 Energized5/8" Super Coil30-603600360037-41230 @ 3600 PSI (250 BAR)Nitrile10 GAL/MIN, 38 L/MINElectrical, ManualN/AAll ports blocked De-Energized, 2-1, 3-4 Energized3600 PSI, 250 BAR
DSL104E1PV
Quote Required
TBD
n/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-15n/a0.4410FluorocarbonC10-4104-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-15 to +400+40085% of rated voltage at 72°F (20°C)Pull and Release5-7All ports blocked De-Energized, 2-1, 3-4 Energized5/8" Super Coil30-603600360037-41230 @ 3600 PSI (250 BAR)Fluorocarbon10 GAL/MIN, 38 L/MINElectrical, ManualN/AAll ports blocked De-Energized, 2-1, 3-4 Energized3600 PSI, 250 BAR
DSL104E1T
Quote Required
TBD
n/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-37 °Cn/a0.2 kg38 L/minD-Ring (Standard)C10-410 Gal/min4-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-35 to +200 °F+200 °F85% of rated voltage at 72°F (20°C) minPush and Twist7-10 NmAll ports blocked De-Energized, 2-1, 3-4 Energized5/8" Super Coil30-60 ms3600 psi3600 psi37-41 lb-ft230 @ 3600 PSI (250 BAR) cm3/minD-Ring (Standard)10 GAL/MIN, 38 L/MINElectrical, ManualN/AAll ports blocked De-Energized, 2-1, 3-4 Energized3600 PSI, 250 BAR
DSL104E1TN
Quote Required
TBD
n/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-30n/a0.4410NitrileC10-4104-WayElectrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-30 to +250+25085% of rated voltage at 72°F (20°C)Push and Twist5-7All ports blocked De-Energized, 2-1, 3-4 Energized5/8" Super Coil30-603600360037-41230 @ 3600 PSI (250 BAR)Nitrile10 GAL/MIN, 38 L/MINElectrical, ManualN/AAll ports blocked De-Energized, 2-1, 3-4 Energized3600 PSI, 250 BAR