Parker’s direct acting 3-way, 2-position spool-type solenoid valves feature a proven design that ensures reliable and predictable performance with low pressure drop and minimal hysteresis. These valves can operate with hydraulic system flows as high as 57 lpm (15 gpm) and pressures up to 350 bar (5000 psi) with normally-open, normally closed, or selector configurations available. Parker’s 3-way, 2-position spool-type solenoid valves are ideal for switching or unloading applications that don’t necessarily require low poppet style leakage, but instead easy solenoid driven directional controls. These valves can be used on a wide range of machinery within the mobile, industrial, or manufacturing markets.

Markets:
• Aerial
• Agriculture
• Construction
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile

Features/Benefits:
• Replaceable one-piece coils with low amp draw
• High flow capacity
• Manual override options
• Standard bodies and cavities
• No dynamic seals
• Low hysteresis
• All external parts zinc plated

Applications:
• Switching applications
• Unloading applications
• Diverter applications

Additional Technical Insight:
Direct acting spool valves are fast to respond to coil voltage and will allow flow passage between 2 ports while blocking the remaining port.  Some leakage will be present due to spool clearances.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceUOMSeal MaterialBody MaterialMinimum Operating TemperatureDivisionMaximum Kinematic ViscosityFunctionWeightMaximum Flow RateFlow RateCavity SizeActuation TypeFor Fluid TypeOperation TypeValve MaterialFilter Efficiency RatingMaximum Operating TemperatureMounting TypeInput VoltageCoil Nut Tightening TorqueFlow DirectionConfigurationOperating TemperatureCoil TypeResponse TimeOverride FunctionalityMaximum Operating PressureMaximum Inlet Pressure RatingLeak RateInstallation TorqueSeal MaterialFlow RateActuation TypeFlow DirectionConfigurationMaximum Inlet Pressure Rating
DSL103BPN
Quote Required
TBD
Nitrilen/a-30Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)3-Way0.4288C10-3Electrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+250Screw in cartridge valve85% of rated voltage at 72°F (20°C)5-72-1 De-energized, 2-3 EnergizedNormally Closed, Selector-34 to +1215/8" Super Coil50-100Pull and Release36003600180 @ 3600 PSI (250 BAR)37-41Nitrile8 GAL/MIN, 30 L/MINElectrical, Manual2-1 De-energized, 2-3 EnergizedNormally Closed, Selector3600 PSI, 250 BAR
DSL103BPV
Quote Required
TBD
Fluorocarbonn/a-15 °FHydraulic Systems Division45-2000 SSU (6 to 420 cSt)3-Way0.19 kg30 L/min8 Gal/minC10-3Electrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+400 °FScrew in cartridge valve85% of rated voltage at 72°F (20°C) min7-10 Nm2-1 De-energized, 2-3 EnergizedNormally Closed, Selector-15 to +400 °F5/8" Super Coil50-100 msPull and Release250 bar250 bar180 @ 3600 PSI (250 BAR) cm3/min37-41 lb-ftFluorocarbon8 GAL/MIN, 30 L/MINElectrical, Manual2-1 De-energized, 2-3 EnergizedNormally Closed, Selector3600 PSI, 250 BAR
DSL103BT
Quote Required
TBD
D-Ring (Standard)n/a-37 °CHydraulic Systems Division45-2000 SSU (6 to 420 cSt)3-Way0.19 kg30 L/min8 Gal/minC10-3Electrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+200 °FScrew in cartridge valve85% of rated voltage at 72°F (20°C) min7-10 Nm2-1 De-energized, 2-3 EnergizedNormally Closed, Selector-35 to +200 °F5/8" Super Coil50-100 msPush and Twist3600 psi250 bar180 @ 3600 PSI (250 BAR) cm3/min50-56 NmD-Ring (Standard)8 GAL/MIN, 30 L/MINElectrical, Manual2-1 De-energized, 2-3 EnergizedNormally Closed, Selector3600 PSI, 250 BAR
DSL103BTN
Quote Required
TBD
Nitrilen/a-34 °CHydraulic Systems Division45-2000 SSU (6 to 420 cSt)3-Way0.42 lb8 Gal/min8 Gal/minC10-3Electrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+121 °CScrew in cartridge valve85% of rated voltage at 72°F (20°C) min7-10 Nm2-1 De-energized, 2-3 EnergizedNormally Closed, Selector-30 to +250 °F5/8" Super Coil50-100 msPush and Twist3600 psi3600 psi180 @ 3600 PSI (250 BAR) cm3/min37-41 lb-ftNitrile8 GAL/MIN, 30 L/MINElectrical, Manual2-1 De-energized, 2-3 EnergizedNormally Closed, Selector3600 PSI, 250 BAR
DSL103BTV
Quote Required
TBD
Fluorocarbonn/a-26 °CHydraulic Systems Division45-2000 SSU (6 to 420 cSt)3-Way0.19 kg8 Gal/min30 L/minC10-3Electrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+204 °CScrew in cartridge valve85% of rated voltage at 72°F (20°C) min7-10 Nm2-1 De-energized, 2-3 EnergizedNormally Closed, Selector-15 to +400 °F5/8" Super Coil50-100 msPush and Twist250 bar3600 psi180 @ 3600 PSI (250 BAR) cm3/min50-56 NmFluorocarbon8 GAL/MIN, 30 L/MINElectrical, Manual2-1 De-energized, 2-3 EnergizedNormally Closed, Selector3600 PSI, 250 BAR
DSL103BV
Quote Required
$61.50
EAFluorocarbonn/a-26 °CHydraulic Systems Division45-2000 SSU (6 to 420 cSt)3-Way0.19 kg30 L/min8 Gal/minC10-3ElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+400 °FScrew in cartridge valve85% of rated voltage at 72°F (20°C) min5-7 lb-ft2-1 De-energized, 2-3 EnergizedNormally Closed, Selector-26 to +204 °C5/8" Super Coil50-100 msn/a3600 psi3600 psi180 @ 3600 PSI (250 BAR) cm3/min50-56 NmFluorocarbon8 GAL/MIN, 30 L/MINElectrical2-1 De-energized, 2-3 EnergizedNormally Closed, Selector3600 PSI, 250 BAR
DSL103C
Quote Required
9 In Stock
$56.06
EAD-Ring (Standard)n/a-37 °CHydraulic Systems Division45-2000 SSU (6 to 420 cSt)3-Way0.19 kg8 Gal/min30 L/minC10-3ElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+93 °CScrew in cartridge valve85% of rated voltage at 72°F (20°C) min5-7 lb-ft3-1 De-energized, 2-1 EnergizedNormally Open-37 to +93 °C5/8" Super Coil50-100 msn/a3600 psi3600 psi120 @ 3600 PSI (250 BAR) cm3/min50-56 NmD-Ring (Standard)8 GAL/MIN, 30 L/MINElectrical3-1 De-energized, 2-1 EnergizedNormally Open3600 PSI, 250 BAR
DSL103CN
Quote Required
TBD
Nitrilen/a-30 °FHydraulic Systems Division45-2000 SSU (6 to 420 cSt)3-Way0.19 kg30 L/min30 L/minC10-3ElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+121 °CScrew in cartridge valve85% of rated voltage at 72°F (20°C) min7-10 Nm3-1 De-energized, 2-1 EnergizedNormally Open-34 to +121 °C5/8" Super Coil50-100 msn/a250 bar250 bar120 @ 3600 PSI (250 BAR) cm3/min50-56 NmNitrile8 GAL/MIN, 30 L/MINElectrical3-1 De-energized, 2-1 EnergizedNormally Open3600 PSI, 250 BAR
DSL103CP
Quote Required
TBD
D-Ring (Standard)n/a-35 °FHydraulic Systems Division45-2000 SSU (6 to 420 cSt)3-Way0.42 lb30 L/min30 L/minC10-3Electrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+93 °CScrew in cartridge valve85% of rated voltage at 72°F (20°C) min7-10 Nm3-1 De-energized, 2-1 EnergizedNormally Open-35 to +200 °F5/8" Super Coil50-100 msPull and Release3600 psi3600 psi120 @ 3600 PSI (250 BAR) cm3/min37-41 lb-ftD-Ring (Standard)8 GAL/MIN, 30 L/MINElectrical, Manual3-1 De-energized, 2-1 EnergizedNormally Open3600 PSI, 250 BAR
DSL103CPN
Quote Required
TBD
Nitrilen/a-30Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)3-Way0.4288C10-3Electrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+250Screw in cartridge valve85% of rated voltage at 72°F (20°C)5-73-1 De-energized, 2-1 EnergizedNormally Open-34 to +1215/8" Super Coil50-100Pull and Release36003600120 @ 3600 PSI (250 BAR)37-41Nitrile8 GAL/MIN, 30 L/MINElectrical, Manual3-1 De-energized, 2-1 EnergizedNormally Open3600 PSI, 250 BAR
DSL103CPV
Quote Required
TBD
Fluorocarbonn/a-15Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)3-Way0.4288C10-3Electrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+400Screw in cartridge valve85% of rated voltage at 72°F (20°C)5-73-1 De-energized, 2-1 EnergizedNormally Open-26 to +2045/8" Super Coil50-100Pull and Release36003600120 @ 3600 PSI (250 BAR)37-41Fluorocarbon8 GAL/MIN, 30 L/MINElectrical, Manual3-1 De-energized, 2-1 EnergizedNormally Open3600 PSI, 250 BAR
DSL103CT
Quote Required
TBD
D-Ring (Standard)n/a-35 °FHydraulic Systems Division45-2000 SSU (6 to 420 cSt)3-Way0.42 lb30 L/min30 L/minC10-3Electrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+200 °FScrew in cartridge valve85% of rated voltage at 72°F (20°C) min7-10 Nm3-1 De-energized, 2-1 EnergizedNormally Open-35 to +200 °F5/8" Super Coil50-100 msPush and Twist250 bar250 bar120 @ 3600 PSI (250 BAR) cm3/min50-56 NmD-Ring (Standard)8 GAL/MIN, 30 L/MINElectrical, Manual3-1 De-energized, 2-1 EnergizedNormally Open3600 PSI, 250 BAR
DSL103CTN
Quote Required
TBD
Nitrilen/a-34 °CHydraulic Systems Division45-2000 SSU (6 to 420 cSt)3-Way0.19 kg8 Gal/min30 L/minC10-3Electrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+121 °CScrew in cartridge valve85% of rated voltage at 72°F (20°C) min7-10 Nm3-1 De-energized, 2-1 EnergizedNormally Open-34 to +121 °C5/8" Super Coil50-100 msPush and Twist250 bar3600 psi120 @ 3600 PSI (250 BAR) cm3/min37-41 lb-ftNitrile8 GAL/MIN, 30 L/MINElectrical, Manual3-1 De-energized, 2-1 EnergizedNormally Open3600 PSI, 250 BAR
DSL103CTV
Quote Required
TBD
Fluorocarbonn/a-26 °CHydraulic Systems Division45-2000 SSU (6 to 420 cSt)3-Way0.19 kg8 Gal/min8 Gal/minC10-3Electrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+204 °CScrew in cartridge valve85% of rated voltage at 72°F (20°C) min5-7 lb-ft3-1 De-energized, 2-1 EnergizedNormally Open-26 to +204 °C5/8" Super Coil50-100 msPush and Twist3600 psi250 bar120 @ 3600 PSI (250 BAR) cm3/min37-41 lb-ftFluorocarbon8 GAL/MIN, 30 L/MINElectrical, Manual3-1 De-energized, 2-1 EnergizedNormally Open3600 PSI, 250 BAR
DSL103CV
Quote Required
TBD
Fluorocarbonn/a-26 °CHydraulic Systems Division45-2000 SSU (6 to 420 cSt)3-Way0.42 lb8 Gal/min30 L/minC10-3ElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+204 °CScrew in cartridge valve85% of rated voltage at 72°F (20°C) min5-7 lb-ft3-1 De-energized, 2-1 EnergizedNormally Open-26 to +204 °C5/8" Super Coil50-100 msn/a3600 psi3600 psi120 @ 3600 PSI (250 BAR) cm3/min50-56 NmFluorocarbon8 GAL/MIN, 30 L/MINElectrical3-1 De-energized, 2-1 EnergizedNormally Open3600 PSI, 250 BAR
DSL103N
Quote Required
82 In Stock
$51.94
EAD-Ring (Standard)n/a-37 °CHydraulic Systems Division45-2000 SSU (6 to 420 cSt)3-Way0.42 lb30 L/min18.8, 30 L/minC10-3ElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+200 °FScrew in cartridge valve85% of rated voltage at 72°F (20°C) min7-10 Nm2-3 De-energized, 2-1 EnergizedNormally Closed, Normally Open, Selector-37 to +93 °C5/8" Super Coil50-100 msn/a3600 psi250 bar180 @ 3600 PSI (250 BAR) cm3/min37-41 lb-ftD-Ring (Standard)5, 8 GAL/MIN, 18.8, 30 L/MINElectrical2-3 De-energized, 2-1 EnergizedNormally Open, Selector3600 PSI, 250 BAR
DSL103NN
Quote Required
TBD
Nitrilen/a-30 °FHydraulic Systems Division45-2000 SSU (6 to 420 cSt)3-Way0.19 kg8 Gal/min5, 8 Gal/minC10-3ElectricalMineral-based or synthetic hydraulic fluidsSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+250 °FScrew in cartridge valve85% of rated voltage at 72°F (20°C) min5-7 lb-ft2-3 De-energized, 2-1 EnergizedNormally Closed, Normally Open, Selector-30 to +250 °F5/8" Super Coil50-100 msn/a250 bar3600 psi180 @ 3600 PSI (250 BAR) cm3/min50-56 NmNitrile5, 8 GAL/MIN, 18.8, 30 L/MINElectrical2-3 De-energized, 2-1 EnergizedNormally Open, Selector3600 PSI, 250 BAR
DSL103NP
Quote Required
TBD
D-Ring (Standard)n/a-35 °FHydraulic Systems Division45-2000 SSU (6 to 420 cSt)3-Way0.19 kg30 L/min18.8, 30 L/minC10-3Electrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+200 °FScrew in cartridge valve85% of rated voltage at 72°F (20°C) min5-7 lb-ft2-3 De-energized, 2-1 EnergizedNormally Closed, Normally Open, Selector-35 to +200 °F5/8" Super Coil50-100 msPull and Release250 bar250 bar180 @ 3600 PSI (250 BAR) cm3/min50-56 NmD-Ring (Standard)5, 8 GAL/MIN, 18.8, 30 L/MINElectrical, Manual2-3 De-energized, 2-1 EnergizedNormally Open, Selector3600 PSI, 250 BAR
DSL103NPN
Quote Required
TBD
Nitrilen/a-35 °CHydraulic Systems Division45-2000 SSU (6 to 420 cSt)3-Way0.42 lb30 L/min18.8, 30 L/minC10-3Electrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+250 °FScrew in cartridge valve85% of rated voltage at 72°F (20°C) min5-7 lb-ft2-3 De-energized, 2-1 EnergizedNormally Closed, Normally Open, Selector-34 to +121 °C5/8" Super Coil50-100 msPull and Release3600 psi3600 psi180 @ 3600 PSI (250 BAR) cm3/min50-56 NmNitrile5, 8 GAL/MIN, 18.8, 30 L/MINElectrical, Manual2-3 De-energized, 2-1 EnergizedNormally Open, Selector3600 PSI, 250 BAR
DSL103NPV
Quote Required
TBD
Fluorocarbonn/a-26 °CHydraulic Systems Division45-2000 SSU (6 to 420 cSt)3-Way0.19 kg8 Gal/min18.8, 30 L/minC10-3Electrical, ManualMineral-based or synthetic hydraulic fluidsSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4+204 °CScrew in cartridge valve85% of rated voltage at 72°F (20°C) min7-10 Nm2-3 De-energized, 2-1 EnergizedNormally Closed, Normally Open, Selector-26 to +204 °C5/8" Super Coil50-100 msPull and Release3600 psi3600 psi180 @ 3600 PSI (250 BAR) cm3/min50-56 NmFluorocarbon5, 8 GAL/MIN, 18.8, 30 L/MINElectrical, Manual2-3 De-energized, 2-1 EnergizedNormally Open, Selector3600 PSI, 250 BAR